AXIS Q2901-E_PT_Mount, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.


AXIS Q2901-E, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1932-E_PT_Mount, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1932-E, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1931-E_PT_Mount, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1931-E, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1765-LE, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS Q1765, version 6.50.2.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

This is a minor LTS release.
These release notes are generic and contains all corrections done for all 6.50 LTS products.

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 6.50.2.3 since 6.50.2.2
======================================

6.50.2.3:C01
General minor improvements to the 6.50 LTS platform.

6.50.2.3:C02
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.50.2.3:C03
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.50.2.3:C04
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.50.2.3:C05
Corrected an issue that caused problems when testing multiple Email recipients.

6.50.2.3:C06
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.50.2.3:C07
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.50.2.3:C08
Corrected an issue that could cause synchronization to AVHS to fail.

6.50.2.3:C09
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.50.2.3:C10
Updated AXIS Video Motion Detection to version 4.2.

6.50.2.3:C11
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.50.2.3:C12
Corrected critical vulnerability ACV-128401.

6.50.2.3:C13
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.50.2.3:C14
Adds PID/program name to network connection list in the Server Report.

6.50.2.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.50.2.3:C16
Corrected an issue that caused the camera to stop streaming on rare occasions.


AXIS Q1942-E, version 7.10.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New features in 7.10.1 since 5.85.4.2
=====================================

7.10.1:F1
Our ONVIF implementation have been improved by adding
GetVideoEncoderConfigurationOptions extension. This makes it possible for an
ONVIF client to get the bitrate range.

7.10.1:F2
It is now possible to specify image rotation via ONVIF video source
configuration

7.10.1:F3
OpenSSL version updated to 1.0.2j.

7.10.1:F4
VMD upgraded to version 4.1.

7.10.1:F5
Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3.

7.10.1:F6
New web-interface with improved usability and broader support of web-clients and
operating systems. For more information please see
https://www.axis.com/global/en/support/technical-notes/browser-support.

7.10.1:F7
The new web-interface supports 12 different pre-installed languages which will
be chosen automatically based on browser settings. Uploading individual language
files is not needed anymore.

Supported Languages:
English - German - French - Spanish - Italian - Portugese - Polish - Russian -
Japanese - Chinese (Mainland) - Chinese (Taiwan) - Korean

7.10.1:F8
If Network Share is setup to use DNS host name as host and if the IP address
changes after mount, the host name is resolved to current IP address.

7.10.1:F9
Added support for ONVIF standardised I/O events.

7.10.1:F10
Edge storage recording robustness is improved with an automatic database repair
feature.

7.10.1:F11
SNMP MIB r/w OID values are saved after reboot.

7.10.1:F12
Improved start-up time.

7.10.1:F13
'The API "Event Handling 1.10" is being removed from this release. If events
have been previously added with this api, they need to be converted using the
"convert" button in the "Action Rules" web page _before_ upgrading. Failing to
do this will result in all event configurations being lost.

7.10.1:F14
Corrected behavior for conditional triggers.

7.10.1:F15
Improved handling for networks with small MTU values.

7.10.1:F16
Improved Zipstream using dynamic frame rate.

7.10.1:F17
Support for ONVIF Profile G.


Corrections in 7.10.1 since 5.85.4.2
====================================

7.10.1:C1
Improved performance when triggerdata enabled in plain config and when no motion
windows have been created.

7.10.1:C2
Corrected handling of #D text overlay, it's no longer needed to specify the
camera source.

7.10.1:C3
Improvements in session ID handling for rtsp streaming. Useful when streaming in
some video clients.

7.10.1:C4
Added link local IPV6 support for NTP.

7.10.1:C5
Fixed Security vulnerability CVE-2016-5195.

7.10.1:C6
Improved HTTP image upload stability in unstable networks.

7.10.1:C7
Improved camera stability when metadata is used.

7.10.1:C8
Fixed a bug that let HTTP notification action rules stop retrying from
contacting the receiving server after a failed attempt.

7.10.1:C9
Improved camera stability when TriggerData is used.

7.10.1:C10
Corrected a bug in the event system that prevented the camera from re-sending
the SMTP notification every 10 seconds in case the receiving server reported an
error.

7.10.1:C11
It is now possible to a select starting point when playing back a recording
while using multicast and H.264.

7.10.1:C12
Improved SD card recording handling.

7.10.1:C13
It is possible to set the RTPS timeout in the URL specifying the stream.

7.10.1:C14
Improved handling of frequent I/O triggering.

7.10.1:C15
Access to Zipstream settings is now available to Operators.

7.10.1:C16
PullMessages now follow the ONVIF specification 9.1.2.

7.10.1:C17
Users with admin permissions can edit ACAP configuration settings.

7.10.1:C18
Camera is reached through HTTPS when NAT traversal is enabled.

7.10.1:C19
Improved synchronization between sound and video when having low fps and long
GOV length.

7.10.1:C20
Improved robustness for Axis ACAPs.

7.10.1:C21
Corrected image corruption issue seen in corridor format.

7.10.1:C22
Fixed script error when naming a privacy mask with åäö.

7.10.1:C23
Added ACAP support for NV12 format.

7.10.1:C24
Corrected possibility to include SPS (Sequence Parameter Set) and PPS (Picture
Parameter Set) in the stream according to ACAP documentation.

7.10.1:C25
Fixed security vulnerability CVE-2015-7547.

7.10.1:C26
Fixed issues with stopped events for manual triggered recording.

7.10.1:C27
Date format now displayed correctly in ACM.

7.10.1:C28
Optimized Network Share polling frequency.

7.10.1:C29
Improved stability in actionengine (tcp notification).

AXIS Q1941-E, version 7.20.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New features in 7.20.1 since 7.10.1
======================================================================

7.20.1:F1
The functionality of enabling Axis DNS Service via control button has been
disabled by default. It can be enabled again using VAPIX.

7.20.1:F2
Changed the default web server authentication from Basic & Digest to Digest
only.

7.20.1:F3
Upon a factory default, the camera will generate a self-signed certificate at
boot and enable HTTPS. This allows clients to use encrypted access from start.
If HTTPS is to be used in daily operations, it is recommended to replace the
generated self-signed certificate with a CA-signed certificate.

7.20.1:F4
Apache web server has been updated to version 2.4.25.

7.20.1:F5
Support for 24bit LPCM audio mode.

7.20.1:F6
OpenSSL has been updated to version 1.0.2k to increase overall minimum cyber
security level.

7.20.1:F7
Support for AXIS SD card health API. The SD card health API allows a client to
track and request the health and wear-out state of an camera with AXIS
Surveillance SD Card.

7.20.1:F8
The Axis Media Control (AMC) is not longer embedded in the product and needs to
be downloaded separately on https://www.axis.com/global/en/support/downloads
/axis-media-control if needed. The Java Applet has been removed as well.

7.20.1:F9
Pressing "Download the server report" in System -> Maintenance will now
automatically attach a snapshot of the image to the .zip file in order to
simplify support.


New features in 7.10.1 since 5.85.4.3
======================================================================

7.10.1:F1
Our ONVIF implementation have been improved by adding
GetVideoEncoderConfigurationOptions extension. This makes it possible for an
ONVIF client to get the bitrate range.

7.10.1:F2
It is now possible to specify image rotation via ONVIF video source
configuration

7.10.1:F3
OpenSSL version updated to 1.0.2j.

7.10.1:F4
VMD upgraded to version 4.1.

7.10.1:F5
Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3.

7.10.1:F6
New web-interface with improved usability and broader support of web-clients and
operating systems. For more information please see
https://www.axis.com/global/en/support/technical-notes/browser-support.

7.10.1:F7
The new web-interface supports 12 different pre-installed languages which will
be chosen automatically based on browser settings. Uploading individual language
files is not needed anymore.

Supported Languages:
English - German - French - Spanish - Italian - Portugese - Polish - Russian -
Japanese - Chinese (Mainland) - Chinese (Taiwan) - Korean

7.10.1:F8
If Network Share is setup to use DNS host name as host and if the IP address
changes after mount, the host name is resolved to current IP address.

7.10.1:F9
Added support for ONVIF standardised I/O events.

7.10.1:F10
Edge storage recording robustness is improved with an automatic database repair
feature.

7.10.1:F11
SNMP MIB r/w OID values are saved after reboot.

7.10.1:F12
Improved start-up time.

7.10.1:F13
'The API "Event Handling 1.10" is being removed from this release. If events
have been previously added with this api, they need to be converted using the
"convert" button in the "Action Rules" web page _before_ upgrading. Failing to
do this will result in all event configurations being lost.

7.10.1:F14
Corrected behavior for conditional triggers.

7.10.1:F15
Improved handling for networks with small MTU values.

7.10.1:F16
Improved Zipstream using dynamic frame rate.

7.10.1:F17
Support for ONVIF Profile G.


Corrections in 7.20.1 since 7.10.1
======================================================================

7.20.1:C1
Corrected an issue that prevented the user from saving a action rule with a
Email Recipient that had SSL enabled.

7.20.1:C2
Corrected a issue resulting in "503 Service Unavailable" when trying to play a
recording from a camera with a specific time range via ONVIF.

7.20.1:C3
Corrected an issue with an additional sign "/" in the absolute upload path of an
SFTP Recipient when saving the action rule causing it to not work correctly.

7.20.1:C4
Corrected an issue when an ONVIF client connected to the camera via digest
authentication.

7.20.1:C5
Fixed critical vulnerability ACV-116267.

7.20.1:C6
Improved camera stability when recording via ONVIF profile G.

AXIS Q2901, version 6.55.1.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 6.55.1.1 since 6.55.1
====================================

6.55.1.1:C1
Fixed critical vulnerability ACV-116267.

AXIS Q8685, version 6.55.1.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.

The new feature "inverted mount" requires a factory default after
upgrading to 6.55.1.3.

New features in 6.55.1.3
======================

6.55.1.3:F1
Support for “inverted” mounting of the camera house on T99A10.
This will change the tilt range from -90 .. 45 to -45 .. 90.

Corrections in 6.55.1.3 since 6.55.1.2
====================================

6.55.1.3:C01
Corrected an issue that made it impossible to play recordings from the camera in Genetec
via ONVIF Profile G.

6.55.1.3:C02
Support for HTTP keep-alive connections via ONVIF. lowers the risk for security focused
network infrastructure or unstable networks to block or drop PTZ control commands.

6.55.1.3:C03
Corrected an issue that let the PTZ control queue ignore an
an anonymous viewer account and deny PTZ control.

6.55.1.3:C04
Improved camera upgrade stability when configuration files become corrupt in rare
occasions.

6.55.1.3:C05
Improved user notification when creating a E-mail recipient that contains wrong domain
information.

6.55.1.3:C06
Corrected an issue that removed an unnecessary warning which was printed in the system log
when a user creates an action rule sending HTTP notification with custom parameter.

6.55.1.3:C07
Product has passed IPv6 compliance.

6.55.1.3:C08
Corrected an issue that displayed system-only users as well under System Options ->
Support -> System Overview.

6.55.1.3:C09
Improved stability when sending VAPIX commands through actionengined.

6.55.1.3:C10
Corrected an issue that caused a wrong time on the camera when Turkey timezone was
configured and Daylight Saving Time was enabled.

6.55.1.3:C11
Corrected an issue that caused guard tours to stop running
in rare occasions.

6.55.1.3:C12
Corrected an issue that could cause a crash in PTZ ACAPs in
rare occasions.

6.55.1.3:C13
Corrected an issue that caused ACAPs that utilize the PTZ
API to stop working in rare occasions.

6.55.1.3:C14
Improved camera stability when using liblicensekey.

6.55.1.3:C15
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
in rare occasions.

6.55.1.3:C16
The Apache webserver has been updated to version 2.4.29 to increase overall minimum
cybersecurity standards.

6.55.1.3:C17
Updated AXIS Video Motion Detection to version 4.1.8.

6.55.1.3:C18
Corrected an issue that prevented the user from login via SSH to the camera after updating
to 6.50.2.

6.55.1.3:C19
Updated R2 GlobalSign Root Certificate to version 20170717. Required to enable Email
recipients using 'Validate server certificate'.

6.55.1.3:C20
Added support for certificates with expiration dates beyond year 2038.

6.55.1.3:C21
General minor improvements to the 6.50 LTS platform.

6.55.1.3:C22
Corrected an issue that let a user modify capture mode without performing the required
restart during the initial set up of the camera.

6.55.1.3:C23
Corrected an issue that caused black images on rare occasions when high loads of Events
are sent to the camera.

6.55.1.3:C24
Support for zoom-tracking in Recorded Guard Tour. Previously only pan/tilt movements were
recorded.

6.55.1.3:C25
Corrected an issue that caused problems when testing multiple Email recipients.

6.55.1.3:C26
Corrected an issue in the trigger data that set Video loss to "Disconnected" as default
initial state even when the camera is initially connected.

6.55.1.3:C27
Corrected an issue that could cause e-mail recipients to not be formatted correctly.

6.55.1.3:C28
Corrected an issue that could cause synchronization to AVHS to fail.

6.55.1.3:C29
Corrected an issue that caused the camera to become unresponsive on rare occasions when
connected to an AVHS system.

6.55.1.3:C30
Updated AXIS Video Motion Detection to version 4.2.

6.55.1.3:C31
Updated AXIS Media Control (AMC) version to 7.3.10.1.

6.55.1.3:C32
Corrected critical vulnerability ACV-128401.

6.55.1.3:C33
Corrected an issue that prevented the user to add the camera to Genetec when HTTPS was
used.

6.55.1.3:C34
Improved day/night shift levels.

6.55.1.3:C35
Adds PID/program name to network connection list in the Server Report.

6.55.1.3:C36
Corrected an issue that let the AXIS Camera Station failover recording not start instantly
on rare occasions.

6.55.1.3:C37
Corrected an issue that caused the camera to stop streaming on rare occasions.

AXIS P7216, version 5.51.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.51.5 since 5.51.2.10
=====================================

5.51.5:C01
Updated R2 GlobalSign Root Certificate to version 20170717.

5.51.5:C02
Corrected an issue that let the camera become unresponsive in rare occasions when
connected to an AVHS system.

5.51.5:C03
Corrected critical vulnerability ACV-128401.

AXIS V5915, version 5.75.1.10

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.75.1.10 since 5.75.1.9
=======================================

5.75.1.10:C01
Corrected critical vulnerability ACV-128401.

AXIS V5914, version 5.75.1.10

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.75.1.10 since 5.75.1.9
=======================================

5.75.1.10:C01
Corrected critical vulnerability ACV-128401.


AXIS P5532-E, version 5.41.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.41.4 since 5.41.3.5
====================================

5.41.4:C01
Corrected critical security vulnerability ACV-128401.

AXIS Q6034-C, version 5.41.3.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.41.3.4 since 5.41.3.3
======================================

5.41.3.4:C01
Corrected critical vulnerability ACV-128401.

AXIS Q6032-C, version 5.41.3.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

NOTE
====================

For latest information about Axis Cybersecurity, see
https://www.axis.com/se/sv/support/product-security.


Corrections in 5.41.3.4 since 5.41.3.3
======================================

5.41.3.4:C01
Corrected critical vulnerability ACV-128401.

AXIS Q1942-E, version 7.30.1.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 7.30.1.1 since 7.30.1
====================================

7.30.1.1:C01
Corrected an issue that presented the Max gain parameter's maximum value as
42dB. In some preceding releases the maximum value was incorrectly presented as
30dB.

AXIS Q1941-E, version 7.30.1.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 7.30.1.1 since 7.30.1
====================================

7.30.1.1:C01
Corrected an issue that presented the Max gain parameter's maximum value as
42dB. In some preceding releases the maximum value was incorrectly presented as
30dB.

Viewing all 9477 articles