Quantcast
Channel: Axis Communications Firmware
Viewing all 9484 articles
Browse latest View live

AXIS Q6035-C PTZ Dome Network Camera, version 5.41.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.41.3
================
5.41.3 is the first official relase for AXIS Q6035-C

Known Bugs/Limitations
================
5.41.3:L01 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.41.3:L02 Maximum brightness will not result in a white image.

5.41.3:L03 Auto tracking might be confused when the IR cut filter is turned on/off.

5.41.3:L04 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.3:L05 The NTP implementation will not synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.41.3:L06 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.41.3:L07 There is no boundary check when entering a motion detection window
name. If the name is more than 1024 charachters long, the parhand
application may restart.

5.41.3:L08 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.3:L09 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.
Workaround: Reload the Live View page.

5.41.3:L10 When setting up a guardtour with Random view order it will
ignore Pause between runs.

5.41.3:L11 The ONVIF command 'gotoHomePosition' will go to the home position at a
very slow speed, it will not use the default speed.

5.41.3:L12 If PTZ limits are changed, the camera must be restarted for the changes
to be applied to the ONVIF API.

5.41.3:L13 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.3:L14 The image is always showed with zero rotation at the OSDI Zone Setup.

5.41.3:L15 Zoom response is very slow when using the mouse scroll wheel in AMC.

5.41.3:L16 Pan/tilt/zoom control does not work using Java Applet if the Control
Queue is enabled.

5.41.3:L17 Live view may display screen tearing (horizontal cut-lines) most
prominent when panning the camera.

5.41.3:L18 Firefox can sometimes show white image flicker at the bottom of the
video stream. This occurs on Windows XP and Windows Vista with Firefox
versions 3.6.3-3.6.6 (possibly on later versions aswell).

5.41.3:L19 When the camera is in RFL-mode (after a failed upgrade), flash
loading it with Firefox may sometimes not work. Use Internet
Explorer instead.

5.41.3:L20 Video stream is lost when clock is synchronizing to a past computer time.

5.41.3:L21 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.3:L22 Stream profile names are limited to alphanumerical characters.

5.41.3:L23 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.41.3:L24 Constant bit rate might fluctuate more than 10%.

5.41.3:L25 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.3:L26 Live view may not work with QuickTime. Try disabling direct3d
acceleration in QuickTime.

5.41.3:L27 In Internet Explorer 6, the live view may stop when pressing buttons
in the live view interface.

5.41.3:L28 Check and repair is only available if the file system is ext4.

5.41.3:L29 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.3:L30 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.3:L31 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the
snapshot. This happens for H.264 stream.

5.41.3:L32 Some versions of Chrome requires a manual refresh of webpage to show
newly created privacy masks and exclude areas.

5.41.3:L33 On some Windows 7 PC's IP Utility doesn't show the DUT when
using IPv6.

5.41.3:L34 Expired or not yet valid client certificates will be uploaded
successfully instead of being rejected.

5.41.3:L35 Issue with an uploaded bitmap overlay which was made partially
transparent unconditionally.

5.41.3:L36 DVM Honeywell generates criticals when accessing a camera during
the boot sequence.

5.41.3:L37 When requesting a videostream using video.cgi, the parameter
color=0 will not result in a black&white image.

5.41.3:L38 Privacy masks needs to be removed and recreated if capture
mode is changed.

5.41.3:L39 Automatic IR Cut Filter will not work if Auto Iris is off.

AXIS Q6034-C PTZ Dome Network Camera, version 5.41.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.41.3
================
5.41.3 is the first official relase for AXIS Q6034-C

Known Bugs/Limitations
================
5.41.3:L01 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.41.3:L02 Maximum brightness will not result in a white image.

5.41.3:L03 Auto tracking might be confused when the IR cut filter is turned on/off.

5.41.3:L04 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.3:L05 The NTP implementation will not synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.41.3:L06 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.41.3:L07 There is no boundary check when entering a motion detection window
name. If the name is more than 1024 charachters long, the parhand
application may restart.

5.41.3:L08 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.3:L09 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.
Workaround: Reload the Live View page.

5.41.3:L10 When setting up a guardtour with Random view order it will
ignore Pause between runs.

5.41.3:L11 The ONVIF command 'gotoHomePosition' will go to the home position at a
very slow speed, it will not use the default speed.

5.41.3:L12 If PTZ limits are changed, the camera must be restarted for the changes
to be applied to the ONVIF API.

5.41.3:L13 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.3:L14 The image is always showed with zero rotation at the OSDI Zone Setup.

5.41.3:L15 Zoom response is very slow when using the mouse scroll wheel in AMC.

5.41.3:L16 Pan/tilt/zoom control does not work using Java Applet if the Control
Queue is enabled.

5.41.3:L17 Live view may display screen tearing (horizontal cut-lines) most
prominent when panning the camera.

5.41.3:L18 Firefox can sometimes show white image flicker at the bottom of the
video stream. This occurs on Windows XP and Windows Vista with Firefox
versions 3.6.3-3.6.6 (possibly on later versions aswell).

5.41.3:L19 When the camera is in RFL-mode (after a failed upgrade), flash
loading it with Firefox may sometimes not work. Use Internet
Explorer instead.

5.41.3:L20 Video stream is lost when clock is synchronizing to a past computer time.

5.41.3:L21 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.3:L22 Stream profile names are limited to alphanumerical characters.

5.41.3:L23 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.41.3:L24 Constant bit rate might fluctuate more than 10%.

5.41.3:L25 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.3:L26 Live view may not work with QuickTime. Try disabling direct3d
acceleration in QuickTime.

5.41.3:L27 In Internet Explorer 6, the live view may stop when pressing buttons
in the live view interface.

5.41.3:L28 Check and repair is only available if the file system is ext4.

5.41.3:L29 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.3:L30 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.3:L31 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the
snapshot. This happens for H.264 stream.

5.41.3:L32 Some versions of Chrome requires a manual refresh of webpage to show
newly created privacy masks and exclude areas.

5.41.3:L33 On some Windows 7 PC's IP Utility doesn't show the DUT when
using IPv6.

5.41.3:L34 Expired or not yet valid client certificates will be uploaded
successfully instead of being rejected.

5.41.3:L35 Issue with an uploaded bitmap overlay which was made partially
transparent unconditionally.

5.41.3:L36 DVM Honeywell generates criticals when accessing a camera during
the boot sequence.

5.41.3:L37 When requesting a videostream using video.cgi, the parameter
color=0 will not result in a black&white image.

5.41.3:L38 Privacy masks needs to be removed and recreated if capture
mode is changed.

5.41.3:L39 Automatic IR Cut Filter will not work if Auto Iris is off.

AXIS Q6032-C PTZ Dome Network Camera, version 5.41.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.41.3
================
5.41.3 is the first official relase for AXIS Q6032-C

Known Bugs/Limitations
================
5.41.3:L01 In PAL version, a black vertical line with several pixels wide is visible
at the right edge of the image. It is not possible to remove with
the X offset parameter.

5.41.3:L02 Maximum brightness will not result in a white image.

5.41.3:L03 Auto tracking might be confused when the IR cut filter is turned on/off.

5.41.3:L04 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.3:L05 The NTP implementation will not synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.41.3:L06 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.41.3:L07 There is no boundary check when entering a motion detection window
name. If the name is more than 1024 charachters long, the parhand
application may restart.

5.41.3:L08 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.3:L09 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.
Workaround: Reload the Live View page.

5.41.3:L10 When setting up a guardtour with Random view order it will
ignore Pause between runs.

5.41.3:L11 Bitmap images have more contrast than the corresponding JPEG images.

5.41.3:L12 Not possible to perform JPEG/BMP requests with aspect ratio
resolutions.

5.41.3:L13 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.3:L14 Stream profile names are limited to alphanumerical characters.

5.41.3:L15 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.41.3:L16 Constant bit rate might fluctuate more than 10%.

5.41.3:L17 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.3:L18 Automatic IR Cut Filter will not work if Auto Iris is off.

5.41.3:L20 Check and repair is only available if the file system is ext4.

5.41.3:L21 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.3:L22 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.3:L23 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the
snapshot. This happens for H.264 stream.

5.41.3:L24 Some versions of Chrome requires a manual refresh of webpage to show
newly created privacy masks and exclude areas.

5.41.3:L25 On some Windows 7 PC's IP Utility doesn't show the DUT when
using IPv6.

5.41.3:L26 Expired or not yet valid client certificates will be uploaded
successfully instead of being rejected.

5.41.3:L27 Issue with an uploaded bitmap overlay which was made partially
transparent unconditionally.

5.41.3:L28 DVM Honeywell generates criticals when accessing a camera during
the boot sequence.

5.41.3:L29 When requesting a videostream using video.cgi, the parameter
color=0 will not result in a black&white image.

5.41.3:L30 Privacy masks needs to be removed and recreated if capture
mode is changed.

AXIS M1013 Network Camera, version 5.40.5.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.5.1
================
5.40.5.1 is the first official production service release for the AXIS M1013/M1014

Corrections since 5.40.5
================
5.40.5.1:L37771 No trigger data for H.264.

5.40.5.1:L37763 Continuous respawning after boot when using fixed white balance.

5.40.5.1:L35729 Collection of Help File errors and misplacements.

5.40.5.1:L33936 Video stream becomes unaccessible while downloading crash report.

5.40.5.1:L32797 IPV6 fails in Onvif.

5.40.5.1:L31337 Add missing scope for ONVIF streaming profile.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not
recommendable.

5.40.3:L24316 Check and repair is only available if the file system is ext4.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot
of small recordings can result in disc full. The automatic clean up will stop
at that point and the user has to manually remove recordings.

5.40.3:L28435 It's not possible to download recordings bigger than 4GB from
the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not
work.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L28738 It's not possible to trigger action rules based on temperature.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.5:L33936 Video stream becomes unaccessible while downloading crash report

5.40.5:L34090 DSCP value for Event/Alarm over IPv4 is always 0

5.40.5:L34091 Changing DSCP values might prompt for password

5.40.5:L34844 Privacy mask can't be added in Chrome

5.40.5:L35612 Video attributes might not be applied after a reboot

5.40.5:L35825 Zoom bar is disabled until using zoom buttons

5.40.5:L35026 Number of different configured video streams are limited by hardware.

AXIS M1143 Network Camera, version 5.40.10.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.10.4
================
5.40.10.4 is the first official production service release for the AXIS M1143

Corrections since 5.40.10
================
5.40.10.4:L31337 Add missing scope for ONVIF streaming profile.

5.40.10.4:L32797 IPV6 fails in Onvif.

5.40.10.4:L34089 IR light settings might be reset when upgrading.

5.40.10.4:L36800 No image when switching profile in live view.

5.40.10.4:L37771 No trigger data for H.264.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not
recommendable.

5.40.3:L24316 Check and repair is only available if the file system is ext4.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot
of small recordings can result in disc full. The automatic clean up will stop
at that point and the user has to manually remove recordings.


5.40.3:L28435 It's not possible to download recordings bigger than 4GB from
the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not
work.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.10:L31556 Event recipient listincorrectly displayed in IE7

5.40.10:L34090 DSCP value for Event/Alarm over IPv4 is always 0

5.40.10:L34091 Changing DSCP values might prompt for password

5.40.10:L35447 Activating IR illumination buttons can impair liveview performance.

5.40.10:L35825 Zoom bar is disabled until using zoom buttons

5.40.10:L35026 Number of different configured video streams are limited by hardware.

5.40.10:L44176 The JPEG images with a rsolution which is not a multiple of 16/8
(width/height) will be truncated to the nearest value. For example if you request
an image with 800x450 resolution then you will get 800x448.

AXIS M1014 Network Camera, version 5.40.5.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.5.1
================
5.40.5.1 is the first official production service release for the AXIS M1014

Corrections since 5.40.5
================
5.40.5.1:L37771 No trigger data for H.264.

5.40.5.1:L37763 Continuous respawning after boot when using fixed white balance.

5.40.5.1:L35729 Collection of Help File errors and misplacements.

5.40.5.1:L33936 Video stream becomes unaccessible while downloading crash report.

5.40.5.1:L32797 IPV6 fails in Onvif.

5.40.5.1:L31337 Add missing scope for ONVIF streaming profile.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not
recommendable.

5.40.3:L24316 Check and repair is only available if the file system is ext4.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot
of small recordings can result in disc full. The automatic clean up will stop
at that point and the user has to manually remove recordings.


5.40.3:L28435 It's not possible to download recordings bigger than 4GB from
the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not
work.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L28738 It's not possible to trigger action rules based on temperature.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.5:L33936 Video stream becomes unaccessible while downloading crash report

5.40.5:L34090 DSCP value for Event/Alarm over IPv4 is always 0

5.40.5:L34091 Changing DSCP values might prompt for password

5.40.5:L34844 Privacy mask can't be added in Chrome

5.40.5:L35612 Video attributes might not be applied after a reboot

5.40.5:L35825 Zoom bar is disabled until using zoom buttons


5.40.5:L35026 Number of different configured video streams are limited by hardware.

AXIS M1144 Network Camera, version 5.40.10.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.10.4
================
5.40.10.4 is the first official production service release for the AXIS M1144

Corrections since 5.40.10
================
5.40.10.4:L31337 Add missing scope for ONVIF streaming profile.

5.40.10.4:L32797 IPV6 fails in Onvif.

5.40.10.4:L34089 IR light settings might be reset when upgrading.

5.40.10.4:L36800 No image when switching profile in live view.

5.40.10.4:L37771 No trigger data for H.264.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not
recommendable.

5.40.3:L24316 Check and repair is only available if the file system is ext4.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot
of small recordings can result in disc full. The automatic clean up will stop
at that point and the user has to manually remove recordings.


5.40.3:L28435 It's not possible to download recordings bigger than 4GB from
the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not
work.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.10:L31556 Event recipient listincorrectly displayed in IE7

5.40.10:L34090 DSCP value for Event/Alarm over IPv4 is always 0

5.40.10:L34091 Changing DSCP values might prompt for password

5.40.10:L35447 Activating IR illumination buttons can impair liveview performance.

5.40.10:L35825 Zoom bar is disabled until using zoom buttons

5.40.10:L35026 Number of different configured video streams are limited by hardware.

5.40.10:L44176 The JPEG images with a rsolution which is not a multiple of 16/8
(width/height) will be truncated to the nearest value. For example if you request
an image with 800x450 resolution then you will get 800x448.

AXIS Q1755 Network Camera, version 5.20.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Added features
================
5.20.2:F01 This release has added support for the Videotec ULISSE PT-head as a new device type
in the Pelco driver.

AXIS T8414 Installation Display, version T8414-315-412-435

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE T8414-315-412-435
================

Axis M3006 Network Camera, version 5.40.13

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.13
================

Known Bugs/Limitations
================
5.40.13:L26468 MJPEG streaming via RTSP does not work in resolution 2048x1536

5.40.13:L29671 Constant bit rate might fluctuate more than 10%.

5.40.13:L36557 Big FPS drop in Cross Line when image rotated.

5.40.13:L37580 The Axis Video Motion Detection application will trigger a motion event if the camera performs any PTZ movements.

M3007 Network Camera, version 5.40.13.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.13
================

Known Bugs/Limitations
================
5.40.13:L26468 MJPEG streaming via RTSP does not work in resolution 2048x1536

5.40.13:L29671 Constant bit rate might fluctuate more than 10%.

5.40.13:L36557 Big FPS drop in Cross Line when image rotated.

5.40.13:L37278 The overview map is not rotated/mirrored when the overview is.

5.40.13:L37285 The overview map might not work correctly on Safari and Chrome.

5.40.13:L37580 The Axis Video Motion Detection application will trigger a motion event if the camera performs any PTZ movements.

AXIS P5532 PTZ Dome Network Camera, version 5.41.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.41.2:F01 Support for a new camera block

Corrections
================
5.41.2:C01 Solved continuous zoom issues

Known Bugs/Limitations
================
5.41.2:L01 In Internet Explorer 6, the live view may stop when pressing buttons
in the live view interface.

5.41.2:L02 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.41.2:L03 When the camera is in RFL-mode (after a failed upgrade), flash
loading it with Firefox may sometimes not work. Use Internet
Explorer instead.

5.41.2:L04 Live view may not work with QuickTime. Try disabling direct3d
acceleration in QuickTime.

5.41.2:L05 Events triggered by multiple input ports may not always work.

5.41.2:L06 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.41.2:L07 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.41.2:L08 The camera can not play an audio clip while a viewer is sending/
receiving audio from the camera.

5.41.2:L09 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.2:L10 An uploaded audio clip must be less than 1.5MB.

5.41.2:L11 An uploaded bitmap overlay is made partially transparent
unconditionally.

5.41.2:L12 With audio enabled, the initial connection latency may increase.

5.41.2:L13 No more than 4 privacy masks can be placed so close together that
they are in the same view at any given time.

5.41.2:L14 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.2:L15 The image is always showed with zero rotation at the OSDI Zone Setup.

5.41.2:L16 Stream profile names are limited to alphanumerical characters.

5.41.2:L17 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.2:L18 A few black pixels can be seen on right edge of the picture in NTSC cameras.

5.41.2:L19 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.2:L20 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.41.2:L21 Constant bit rate might fluctuate more than 10%.

5.41.2:L22 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.2:L23 It is recommended to unmount the SD Card before ejecting it.

5.41.2:L24 Recordings made on the SD Card with firmware version earlier than 5.20
will not be readable from the 5.40 firmware. Backup important recordings and
reformat the SD Card after firmware upgrade.

5.41.2:L25 Check and repair is only available if the file system is ext4.

5.41.2:L26 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.2:L27 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

AXIS P5532-E PTZ Dome Network Camera, version 5.41.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.41.2:F01 Support for a new camera block

Corrections
================
5.41.2:C01 Solved continuous zoom issues

Known Bugs/Limitations
================
5.41.2:L01 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.41.2:L02 An uploaded bitmap overlay is made partially transparent
unconditionally (black color).

5.41.2:L03 Maximum brightness will not result in a white image.

5.41.2:L04 No more than 4 privacy masks can be placed so close together that
they are in the same view at any given time.

5.41.2:L05 Stream profile names are limited to alphanumerical characters.

5.41.2:L06 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.2:L07 Using ONVIF, the camera declares that is supports the Normalized
Digital Zoom spaces but the camera does not and should not support
those spaces.

5.41.2:L08 The ONVIF command 'gotoHomePosition' will go to the home position at a
very slow speed, it will not use the default speed.

5.41.2:L09 If PTZ limits are changed the camera must be restarted for the changes
to be applied to the ONVIF API.

5.41.2:L10 If a Go to Preset movement includes an AutoFlip, the image will
freeze during the whole movement. When the movement is done, the stream
will start again. Movement will also be done at full speed, regardles
of the current speed configuration.

5.41.2:L11 Automatic IR Cut Filter will not work if Auto Iris is off.

5.41.2:L12 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.2:L13 Removing a Guard Tour while another Guard Tour is running will stop
and restart the ongoing Guard Tour.

5.41.2:L14 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.2:L15 The image is always showed with zero rotation at the OSDI Zone Setup.

5.41.2:L16 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.41.2:L17 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.41.2:L18 If no Home Position is set, the camera will point straight down after
booting.

5.41.2:L19 The 60Hz model has few pixels wide black column at the side of the
image.

5.41.2:L20 Zoom response is very slow when using the mouse scroll wheel in AMC.

5.41.2:L21 Pan/tilt/zoom control does not work using Java Applet if the Control
Queue is enabled.

5.41.2:L22 Firefox can sometimes show white image flicker at the bottom of the
video stream. This occurs on Windows XP and Windows Vista with Firefox
versions 3.6.3-3.6.6 (possibly on later versions aswell).

5.41.2:L23 When the camera is in RFL-mode (after a failed upgrade), flash
loading it with Firefox may sometimes not work. Use Internet
Explorer instead.

5.41.2:L24 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.2:L25 Frame Size Control does not affect size of the snapshot taken with the upper
right control that can be added to the Live View.

5.41.2:L26 Constant bit rate might fluctuate more than 10%.

5.41.2:L27 Events triggered at the same time, will by default settings share the same
filename. This may result in upload of corrupted image.

5.41.2:L28 It is recommended to unmount the SD Card before ejecting it.

5.41.2:L29 Recordings made on the SD Card with firmware version earlier than 5.20
will not be readable from the 5.40 firmware. Backup important recordings and
reformat the SD Card after firmware upgrade.

5.41.2:L30 Check and repair is only available if the file system is ext4.

5.41.2:L31 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.2:L32 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

AXIS Q7411 Network Camera, version 5.40.13.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40
================

Corrections since 5.40.13.1
================
5.40.13.1:C1 Created a new port type for coax PTZ controlled devices. Users must upgrade the Pelco_Coax-4.1 driver to Pelco_Coax_Port-5.0 after firmware upgrade.

5.40.13.1:C2. A new parameter, 'auto' has been added to ptzupgrader.cgi. This parameter is used to automatically match the port required by the driver to the ports available in the system. See Vapix documentation for more details.

5.40.13.1:C3 The PTZ home preset position does not work after a restart.

5.40.13.1:C4 I/O outputs becomes active when the unit is restarted. The problem only occurr during startup, once the unit is up and running again the I/O outputs take on the state as configured by the user.

Known Bugs/Limitations
================
5.40.13.2:L1 Cannot record audio clip with no wait time. You must wait at least 1 second.

5.40.13.2:L2 Constant bit rate might fluctuate more than 10%.

5.40.13.2:L3 Frame Size Control does not affect the size of the snapshot taken with the upper right control that can be added to the Live View.

5.40.13.2:L4 If the SD card is locked while there is a continuous recording ongoing and then the recording is stopped while the card is still locked, the recording continues and can’t be stopped

5.40.13.2:L5 It is not possible to select starting point when playing back a recording while using multicast and h264.

5.40.13.2:L6 The Axis Video Motion Detection application will trigger a motion event if the camera performs any PTZ movements.

5.40.13.2:L7 Event trigger data is sent even though user data is disabled

5.40.13.2:L8 For actions based on PTZ events it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in file names for network share uploads.

5.40.13.2:L9 Requesting an fps value larger than 30 will always give double the full normal fps for the given video type. Requesting any fps value larger than 30 will thus give 50/60 fps for a PAL/NTSC source.

AXIS P5534-E PTZ Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.4:I01 Improved stability with AVHS and VMD 2.1.

Known Bugs/Limitations
================
5.40.9.3:L01 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera

5.40.9.3:L02 An uploaded bitmap overlay is made partially transparent
unconditionally (black color).

5.40.9.3:L03 Maximum brightness will not result in a white image.

5.40.9.3:L04 No more than 4 privacy masks can be placed so close together that
they are in the same view at any given time.

5.40.9.3:L05 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L06 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.3:L07 Using ONVIF, the camera declares that is supports the Normalized
Digital Zoom spaces but the camera does not and should not support
those spaces.

5.40.9.3:L08 The ONVIF command 'gotoHomePosition' will go to the home position at a
very slow speed, it will not use the default speed.

5.40.9.3:L09 If PTZ limits are changed, the camera must be restarted for the changes
to be applied to the ONVIF API.

5.40.9.3:L10 If a Go to Preset movement includes an AutoFlip, the image will
freeze during the whole movement. When the movement is done, the stream
will start again. Movement will also be done at full speed, regardles
of the current speed configuration.

5.40.9.3:L11 Automatic IR Cut Filter will not work if Auto Iris is off.

5.40.9.3:L12 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.40.9.3:L13 Removing a Guard Tour while another Guard Tour is running will stop
and restart the ongoing Guard Tour.

5.40.9.3:L14 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.40.9.3:L15 The image is always showed with zero rotation at the OSDI Zone Setup.

5.40.9.3:L16 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.40.9.3:L17 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.3:L18 Constant bit rate might fluctuate more than 10%.

5.40.9.3:L19 Zoom response is very slow when using the mouse scroll wheel in AMC.

5.40.9.3:L20 Pan/tilt/zoom control does not work using Java Applet if the Control
Queue is enabled.

5.40.9.3:L21 Live view may display screen tearing (horizontal cut-lines) most
prominent when panning the camera.

5.40.9.3:L22 Firefox can sometimes show white image flicker at the bottom of the
video stream. This occurs on Windows XP and Windows Vista with Firefox
versions 3.6.3-3.6.6 (possibly on later versions aswell).

5.40.9.3:L23 Color parameter has no effect when pulling RTSP stream with color=0.

5.40.9.3:L24 Frame Size Control does not affect size of the snapshot taken with the upper
right control that can be added to the Live View.

5.40.9.3:L25 It is recommended to unmount the SD Card before ejecting it.

5.40.9.3:L26 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.3:L27 Check and repair is only available if the file system is ext4.

5.40.9.3:L28 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.3:L29 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

AXIS P3363, version 5.40.17

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5_40_17
================

Corrections since 5.40.10.5
================
5_40_17:C01
Several improvements for stability

5_40_17:C02
A data timeout problem that could occur when saving to SD card has been solved

5_40_17:C03
A stability problem that may occur during continuous SD card recording,
has been solved by preventing memory fragmentation.

5_40_17:C04
Default compression for H.264 has been changed in order to decrease the bitrate.

5_40_17:C05
Fix issue with camera loosing focus after restart.

5_40_17:C06
Increase autofocus range, to better handle uncalibrated units.

Features
================

Known Bugs/Limitations
================
5_40_17:L01
The resolutions of the pre-defined profile has changed. Quality uses the maximum resolution. Balanced and bandwidth uses default resolution, which in this case is equal to the maximum resolution. Mobile uses the minimum resolution.

AXIS P3353, version 5.40.17

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5_40_17
================

Corrections since 5.40.10.5
================
5_40_17:C01
Several improvements for stability

5_40_17:C02
A data timeout problem that could occur when saving to SD card has been solved

5_40_17:C03
A stability problem that may occur during continuous SD card recording,
has been solved by preventing memory fragmentation.

5_40_17:C04
Default compression for H.264 has been changed in order to decrease the bitrate.

5_40_17:C05
Fix issue with camera loosing focus after restart.

5_40_17:C06
Increase autofocus range, to better handle uncalibrated units.

Features
================

Known Bugs/Limitations
================
5_40_17:L01
The resolutions of the pre-defined profile has changed. Quality uses the maximum resolution. Balanced and bandwidth uses default resolution, which in this case is equal to the maximum resolution. Mobile uses the minimum resolution.

AXIS P3364, AXIS P3364-L, version 5.40.17

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5_40_17
================

Corrections since 5.40.10.5
================
5_40_17:C01
Several improvements for stability

5_40_17:C02
A data timeout problem that could occur when saving to SD card has been solved

5_40_17:C03
A stability problem that may occur during continuous SD card recording,
has been solved by preventing memory fragmentation.

5_40_17:C04
Default compression for H.264 has been changed in order to decrease the bitrate.

5_40_17:C05
Fix issue with camera loosing focus after restart.

5_40_17:C06
Increase autofocus range, to better handle uncalibrated units.

Features
================

Known Bugs/Limitations
================
5_40_17:L01
The resolutions of the pre-defined profile has changed. Quality uses the maximum resolution. Balanced and bandwidth uses default resolution, which in this case is equal to the maximum resolution. Mobile uses the minimum resolution.

AXIS P3354, version 5.40.17

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5_40_17
================

Corrections since 5.40.10.5
================
5_40_17:C01
Several improvements for stability

5_40_17:C02
A data timeout problem that could occur when saving to SD card has been solved

5_40_17:C03
A stability problem that may occur during continuous SD card recording,
has been solved by preventing memory fragmentation.

5_40_17:C04
Default compression for H.264 has been changed in order to decrease the bitrate.

5_40_17:C05
Fix issue with camera loosing focus after restart.

5_40_17:C06
Increase autofocus range, to better handle uncalibrated units.

Features
================

Known Bugs/Limitations
================
5_40_17:L01
The resolutions of the pre-defined profile has changed. Quality uses the maximum resolution. Balanced and bandwidth uses default resolution, which in this case is equal to the maximum resolution. Mobile uses the minimum resolution.

AXIS Q1602/Q1602-E Network Camera, version 5.40.3.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements
================
5.40.3.4:I01 Improved events stability (TCP notifications, SD-cards).

5.40.3.4:I02 Improved streaming (video memory adjustment, correct UDP checksums,
TTL value for Always Multicast as well as receiver's MTU are now
taken into account).

Known Bugs/Limitations
================
5.40.3.4:L01 Removing and reinserting SD card during recording is not
recommendable.

5.40.3.4:L02 With audio enabled, the initial connection latency is increased.

5.40.3.4:L03 Remote back focus operation will be disabled when the temperature
is too low. Information will be shown in system log.

5.40.3.4:L05 A combination of a high bandwidth continuous recording and a lot of small recodings
can result in disc full. The automatic clean up will stop at the point and the user
have to manualy remove recordings.

5.40.3.4:L06 If you set max gain to a low value, e.g. 0, the IR cut filter
may not switch back on automatically.

5.40.3.4:L07 Using modifiers like %c in a network share upload event does not
work.

5.40.3.4:L08 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.3.4:L09 The micophone input level is by default quite high.
Workaround: Lower the input gain to reach an appropriate level

5.40.3.4:L10 Custom Firmware cannot be loaded
Viewing all 9484 articles