AXIS P1346/P1346-E Network Camera, version 5.40.9.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.4 since 5.40.9.3
================
5.40.9.4:I01 Better constant bitrate algorithm.

5.40.9.4:I02 Fix for SD-card corruption.

5.40.9.4:I03 ONVIF stability fixes.

5.40.9.4:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.4:I05 TTL value for always multicast is taken into account.

5.40.9.4:I06 SDP for always multicast available to viewer users.

5.40.9.4:I07 Solved connection issues to AVHS servers.

5.40.9.4:I08 Improved TCP notification stability.

5.40.9.4:I09 Improved stability when using AxisNS.

5.40.9.4:I10 No extra backslash added on a FTP server when using a domainusername scheme.

Known Bugs/Limitations
================
5.40.9.4:L01 It is recommended to unmount the SD Card before ejecting it.

5.40.9.4:L02 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.4:L03 Remote back focus operation will be disabled when temperature
is too low. Information will be shown in the system log.

5.40.9.4:L04 Check and repair is only available if the file system is ext4.

5.40.9.4:L05 Recording streams with a total bit rate above
12Mbit/sec to SD Card may cause missing frames/sequences.

5.40.9.4:L06 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.4:L07 With audio enabled, the initial connection latency increases.

5.40.9.4:L08 Sometimes IR cut filter switches between ON/OFF after factory default when
illuminance is 7-10 lux.

5.40.9.4:L09 Color parameter has no effect when pulling RTSP stream with color=0.

5.40.9.4:L10 Sensor capture mode should be set during the initial product
configuration as it affects the available resolutions. Changing it in
real time requires other resolution related configuration changes on the
camera and possibly a recording software. For example, if a resolution
that is not available for one capture mode is requested, the reply will
be "bad request".

5.40.9.4:L11 It may be necessary to disable both "Advanced video
rendering" and "Enable overlays" in the Control Panel -> AXIS Media
Control in order to get a smoother H.264 video in Live view in 3MP and HDTV highest
resolution.

5.40.9.4:L12 Local recording playback fails when using Motion JPEG with resolution
2048x1536 and associated audio. Workaround: Use H.264 instead.

AXIS Q6034 PTZ Dome Network Camera, version 5.41.1.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.41.1.1 since 5.41.1
================
5.41.1.1:I01 Better constant bitrate algorithm.

5.41.1.1:I02 Fix for SD-card corruption.

5.41.1.1:I03 Fix for guard tour crashes and PTZ startup issues.

5.41.1.1:I04 ONVIF stability fixes.

5.41.1.1:I05 New version of libupnp without buffer overflow vulnerabilities.

5.41.1.1:I06 Improved stability with AVHS and VMD 2.1.

5.41.1.1:I07 No need for a viewer user's password to be entered several times to access Live View.

5.41.1.1:I08 TTL value for always multicast is taken into account.

5.41.1.1:I09 SDP for always multicast available to viewer users.

5.41.1.1:I10 Solved connection issues to AVHS servers.

5.41.1.1:I11 No extra backslash added on a FTP server when using a domainusername scheme.

5.41.1.1:I12 Improved stability when using AxisNS.

5.41.1.1:I13 Improved TCP notification stability.

5.41.1.1:I14 Fix for color displacements in H264.

Known Bugs/Limitations
================
5.41.1.1:L01 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.41.1.1:L02 Maximum brightness will not result in a white image.

5.41.1.1:L03 Auto tracking might be confused when the IR cut filter is turned on/off.

5.41.1.1:L04 Pan/tilt coordinate directions presented in the text overlay (#x #y)
will not be rotated along with the image when rotation is 180.

5.41.1.1:L05 The NTP implementation will not synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.41.1.1:L06 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.41.1.1:L07 There is no boundary check when entering a motion detection window
name. If the name is more than 1024 charachters long, the parhand
application may restart.

5.41.1.1:L08 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.1.1:L09 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.
Workaround: Reload the Live View page.

5.41.1.1:L10 When setting up a guardtour with Random view order it will
ignore Pause between runs.

5.41.1.1:L11 The ONVIF command 'gotoHomePosition' will go to the home position at a
very slow speed, it will not use the default speed.

5.41.1.1:L12 If PTZ limits are changed, the camera must be restarted for the changes
to be applied to the ONVIF API.

5.41.1.1:L13 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.1.1:L14 The image is always showed with zero rotation at the OSDI Zone Setup.

5.41.1.1:L15 Zoom response is very slow when using the mouse scroll wheel in AMC.

5.41.1.1:L16 Pan/tilt/zoom control does not work using Java Applet if the Control
Queue is enabled.

5.41.1.1:L17 Live view may display screen tearing (horizontal cut-lines) most
prominent when panning the camera.

5.41.1.1:L18 Firefox can sometimes show white image flicker at the bottom of the
video stream. This occurs on Windows XP and Windows Vista with Firefox
versions 3.6.3-3.6.6 (possibly on later versions aswell).

5.41.1.1:L19 When the camera is in RFL-mode (after a failed upgrade), flash
loading it with Firefox may sometimes not work. Use Internet
Explorer instead.

5.41.1.1:L20 Video stream is lost when clock is synchronizing to a past computer time.

5.41.1.1:L21 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.1.1:L22 Stream profile names are limited to alphanumerical characters.

5.41.1.1:L23 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.41.1.1:L24 An uploaded audio clip must be less than 1.5MB.

5.41.1.1:L25 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.1.1:L26 With audio enabled, the initial connection latency increases.

5.41.1.1:L27 Recordings made with firmware version 5.15 will not be readable
on the SD Card from the 5.41.1 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.41.1.1:L28 Check and repair is only available if the file system is ext4.

5.41.1.1:L29 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.1.1:L30 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.1.1:L31 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the
snapshot. This happens for H.264 stream.

5.41.1.1:L32 Some versions of Chrome requires a manual refresh of webpage to show
newly created privacy masks and exclude areas.

5.41.1.1:L33 On some Windows 7 PC's IP Utility doesn't show the DUT when
using IPv6.

5.41.1.1:L34 Expired or not yet valid client certificates will be uploaded
successfully instead of being rejected.

5.41.1.1:L35 Issue with an uploaded bitmap overlay which was made partially
transparent unconditionally.

5.41.1.1:L36 DVM Honeywell generates criticals when accessing a camera during
the boot sequence.

5.41.1.1:L37 When requesting a videostream using video.cgi, the parameter
color=0 will not result in a black&white image.

5.41.1.1:L38 Privacy masks needs to be removed and recreated if capture
mode is changed.

5.41.1.1:L39 Automatic IR Cut Filter will not work if Auto Iris is off.

5.41.1.1:L40 In Internet Explorer 6, the live view may stop when pressing buttons
in the live view interface.

5.41.1.1:L41 Live view may not work with QuickTime. Try disabling direct3d
acceleration in QuickTime.

5.41.1.1:L42 Events triggered by multiple input ports may not always work.

5.41.1.1:L43 The camera can not play an audio clip while a viewer is sending/
receiving audio from to/from the camera.

AXIS P3346 Fixed Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 Fix for SD-card corruption.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I10 Improved stability when using AxisNS.

5.40.9.3:I11 Improved TCP notification stability.

Known Bugs/Limitations
================
5.40.9.3:L01 It is recommended to unmount the SD Card before ejecting it.

5.40.9.3:L02 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.3:L03 Remote back focus operation will be disabled when temperature
is too low. Information will be shown in the system log.

5.40.9.3:L04 Check and repair is only available if the file system is ext4.

5.40.9.3:L05 Recording streams with a total bit rate above
12Mbit/sec to SD Card may cause missing frames/sequences.

5.40.9.3:L06 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.3:L07 With audio enabled, the initial connection latency increases.

5.40.9.3:L08 Sometimes IR cut filter switches between ON/OFF after factory default when
illuminance is 7-10 lux.

5.40.9.3:L09 Color parameter has no effect when pulling RTSP stream with color=0.

AXIS P5534 PTZ Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 Fix for SD-card corruption.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I10 Improved stability when using AxisNS.

5.40.9.3:I11 Improved TCP notification stability.

5.40.9.3:I12 No need for a viewer user's password to be entered several times to access Live View.

5.40.9.3:I13 Fix for color displacements in H264.

5.40.9.3:I14 Fix for guard tour crashes and PTZ startup issues.

Known Bugs/Limitations
================
5.40.9.3:L01 In Internet Explorer 6, the live view may stop when pressing buttons
in the live view interface.

5.40.9.3:L02 Live view may not work with QuickTime. Try disabling direct3d.

5.40.9.3:L03 Events triggered by multiple input ports may not always work.

5.40.9.3:L04 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.40.9.3:L05 The camera can not play an audio clip while a viewer is sending/
receiving audio from the camera.

5.40.9.3:L06 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.40.9.3:L07 An uploaded audio clip must be less than 1.5MB.

5.40.9.3:L08 An uploaded bitmap overlay is made partially transparent
unconditionally.

5.40.9.3:L09 To playback Matroska files generated by the camera on a computer, you
need to have the configuration file ('.conf') in the same folder as
the Matroska file ('.mkv'). For more information
see: http://www.axis.com/techsup/software/matroska/files/readme.txt

5.40.9.3:L10 With audio enabled, the initial connection latency may increase.

5.40.9.3:L11 No more than 4 privacy masks can be placed so close together that
they are in the same view at any given time.

5.40.9.3:L12 The image is always showed with zero rotation at the OSDI Zone Setup.

5.40.9.3:L13 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L14 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.3:L15 A few black pixels can be seen in right edge of the picture in NTSC cameras.

5.40.9.3:L16 The color setting does not go as high as on Q6032-E. It is not possible
to get much color in the image.

5.40.9.3:L17 Color parameter has no effect when pulling RTSP stream with color=0.

5.40.9.3:L18 Frame Size Control does not affect size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.3:L19 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.3:L20 Events triggered at the same time, will by default settings
share the same filename. That might result in upload of corrupted
image.

5.40.9.3:L21 It is recommended to unmount the SD Card before ejecting it.

5.40.9.3:L22 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.3:L23 Check and repair is only available if the file system is ext4.

5.40.9.3:L24 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

AXIS M1113 Fixed Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 Improved TCP notification stability.

5.40.9.3:I10 Improved stability when using AxisNS.

Known Bugs/Limitations
================
5.40.9.3:L01 The effect of backlight compensation on/off may not be noticable.

5.40.9.3:L02 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L03 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.40.9.3:L04 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.3:L05 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.3:L06 Video stream lost when clock is synchronizing to a past computer time.

5.40.9.3:L07 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.3:L08 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.3:L09 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.3:L10 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

AXIS M1104 Fixed Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 Improved TCP notification stability.

5.40.9.3:I10 Improved stability when using AxisNS.

Known Bugs/Limitations
================
5.40.9.3:L01 The effect of backlight compensation on/off may not be noticable.

5.40.9.3:L02 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L03 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.40.9.3:L04 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.3:L05 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.3:L06 Video stream lost when clock is synchronizing to a past computer time.

5.40.9.3:L07 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.3:L08 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.3:L09 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.3:L10 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

AXIS M1114 Fixed Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 Improved TCP notification stability.

5.40.9.3:I10 Improved stability when using AxisNS.

Known Bugs/Limitations
================
5.40.9.3:L01 The effect of backlight compensation on/off may not be noticable.

5.40.9.3:L02 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L03 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.40.9.3:L04 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.3:L05 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.3:L06 Video stream lost when clock is synchronizing to a past computer time.

5.40.9.3:L07 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.3:L08 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.3:L09 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.3:L10 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

AXIS M1103 Fixed Dome Network Camera, version 5.40.9.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.3 since 5.40.9.2
================
5.40.9.3:I01 Better constant bitrate algorithm.

5.40.9.3:I02 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.3:I03 ONVIF stability fixes.

5.40.9.3:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.3:I05 Improved stability with AVHS and VMD 2.1.

5.40.9.3:I06 TTL value for always multicast is taken into account.

5.40.9.3:I07 SDP for always multicast available to viewer users.

5.40.9.3:I08 Solved connection issues to AVHS servers.

5.40.9.3:I09 Improved TCP notification stability.

5.40.9.3:I10 Improved stability when using AxisNS.

Known Bugs/Limitations
================
5.40.9.3:L01 The effect of backlight compensation on/off may not be noticable.

5.40.9.3:L02 Stream profile names are limited to alphanumerical characters.

5.40.9.3:L03 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.40.9.3:L04 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.3:L05 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.3:L06 Video stream lost when clock is synchronizing to a past computer time.

5.40.9.3:L07 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.3:L08 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.3:L09 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.3:L10 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

AXIS P3344 Fixed Dome Network Camera, version 5.40.9.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.5 since 5.40.9.4
================
5.40.9.5:I01 Better constant bitrate algorithm.

5.40.9.5:I02 Fix for SD-card corruption.

5.40.9.5:I03 ONVIF stability fixes.

5.40.9.5:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.5:I05 TTL value for always multicast is taken into account.

5.40.9.5:I06 SDP for always multicast available to viewer users.

5.40.9.5:I07 Solved connection issues to AVHS servers.

5.40.9.5:I08 Improved TCP notification stability.

5.40.9.5:I09 Improved stability when using AxisNS.

5.40.9.5:I10 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.5:I11 Added support for power line frequency.

Known Bugs/Limitations
================
5.40.9.5:L01 It is recommended to unmount the SD Card before ejecting it.

5.40.9.5:L02 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.5:L03 Remote back focus operation will be disabled when temperature
is too low. Information will be shown in the system log.

5.40.9.5:L04 Check and repair is only available if the file system is ext4.

5.40.9.5:L05 Recording streams with a total bit rate above
12Mbit/sec to SD Card may cause missing frames/sequences.

5.40.9.5:L06 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.5:L07 With audio enabled, the initial connection latency increases.

5.40.9.5:L08 Sometimes IR cut filter switches between ON/OFF after factory default when
illuminance is 7-10 lux.

5.40.9.5:L09 Color parameter has no effect when pulling RTSP stream with color=0.

AXIS P3343 Fixed Dome Network Camera, version 5.40.9.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.9.5 since 5.40.9.4
================
5.40.9.5:I01 Better constant bitrate algorithm.

5.40.9.5:I02 Fix for SD-card corruption.

5.40.9.5:I03 ONVIF stability fixes.

5.40.9.5:I04 New version of libupnp without buffer overflow vulnerabilities.

5.40.9.5:I05 TTL value for always multicast is taken into account.

5.40.9.5:I06 SDP for always multicast available to viewer users.

5.40.9.5:I07 Solved connection issues to AVHS servers.

5.40.9.5:I08 Improved TCP notification stability.

5.40.9.5:I09 Improved stability when using AxisNS.

5.40.9.5:I10 No extra backslash added on a FTP server when using a domainusername scheme.

5.40.9.5:I11 Added support for power line frequency.

Known Bugs/Limitations
================
5.40.9.5:L01 It is recommended to unmount the SD Card before ejecting it.

5.40.9.5:L02 Recordings made with firmware earlier than 5.20 will not be readable
on the SD Card from the 5.40 firmware. Backup important recordings and
reformat the SD Card after the firmware upgrade.

5.40.9.5:L03 Remote back focus operation will be disabled when temperature
is too low. Information will be shown in the system log.

5.40.9.5:L04 Check and repair is only available if the file system is ext4.

5.40.9.5:L05 Recording streams with a total bit rate above
12Mbit/sec to SD Card may cause missing frames/sequences.

5.40.9.5:L06 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.5:L07 With audio enabled, the initial connection latency increases.

5.40.9.5:L08 Sometimes IR cut filter switches between ON/OFF after factory default when
illuminance is 7-10 lux.

5.40.9.5:L09 Color parameter has no effect when pulling RTSP stream with color=0.

AXIS P1204, P1214, P1214-E Network camera, version 5.40.12.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.12.1 since 5.40.12
================
5.40.12.1:I01 Fix for SD-card corruption.

5.40.12.1:I02 Solved connection issues to AVHS servers.

5.40.12.1:I03 New version of libupnp without buffer overflow vulnerabilities.

5.40.12.1:I04 Improved stability with AVHS and VMD 2.1.

5.40.12.1:I05 Improved stability when using AxisNS.

5.40.12.1:I06 Improved TCP notification stability.

Known Bugs/Limitations
================
5.40.12.1:L01 Event trigger data is sent even though user data is disabled.

5.40.12.1:L02 Date & Time gets defaulted when preforming a Factory Restore.

5.40.12.1:L03 It is not possible to select starting point when playing
back a recording while using multicast and h264.

5.40.12.1:L04 If the SD card is locked while there is a continuous
recording ongoing and then the recording is stopped while
the card is still locked, the recording continues and can
not be stopped.

5.40.12.1:L05 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

AXIS P1204, P1214, P1214-E Network camera, version 5.40.12.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.12.1 since 5.40.12
================
5.40.12.1:I01 Fix for SD-card corruption.

5.40.12.1:I02 Solved connection issues to AVHS servers.

5.40.12.1:I03 New version of libupnp without buffer overflow vulnerabilities.

5.40.12.1:I04 Improved stability with AVHS and VMD 2.1.

5.40.12.1:I05 Improved stability when using AxisNS.

5.40.12.1:I06 Improved TCP notification stability.

Known Bugs/Limitations
================
5.40.12.1:L01 Event trigger data is sent even though user data is disabled.

5.40.12.1:L02 Date & Time gets defaulted when preforming a Factory Restore.

5.40.12.1:L03 It is not possible to select starting point when playing
back a recording while using multicast and h264.

5.40.12.1:L04 If the SD card is locked while there is a continuous
recording ongoing and then the recording is stopped while
the card is still locked, the recording continues and can
not be stopped.

5.40.12.1:L05 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

AXIS P1204, P1214, P1214-E Network camera, version 5.40.12.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.12.1 since 5.40.12
================
5.40.12.1:I01 Fix for SD-card corruption.

5.40.12.1:I02 Solved connection issues to AVHS servers.

5.40.12.1:I03 New version of libupnp without buffer overflow vulnerabilities.

5.40.12.1:I04 Improved stability with AVHS and VMD 2.1.

5.40.12.1:I05 Improved stability when using AxisNS.

5.40.12.1:I06 Improved TCP notification stability.

Known Bugs/Limitations
================
5.40.12.1:L01 Event trigger data is sent even though user data is disabled.

5.40.12.1:L02 Date & Time gets defaulted when preforming a Factory Restore.

5.40.12.1:L03 It is not possible to select starting point when playing
back a recording while using multicast and h264.

5.40.12.1:L04 If the SD card is locked while there is a continuous
recording ongoing and then the recording is stopped while
the card is still locked, the recording continues and can
not be stopped.

5.40.12.1:L05 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

AXIS M2014-E Network camera, version 5.40.12.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Improvements in 5.40.12.1 since 5.40.12
================
5.40.12.1:I01 Fix for SD-card corruption.

5.40.12.1:I02 Solved connection issues to AVHS servers.

5.40.12.1:I03 New version of libupnp without buffer overflow vulnerabilities.

5.40.12.1:I04 Improved stability with AVHS and VMD 2.1.

5.40.12.1:I05 Improved stability when using AxisNS.

5.40.12.1:I06 Improved TCP notification stability.

Known Bugs/Limitations
================
5.40.12.1:L01 Event trigger data is sent even though user data is disabled.

5.40.12.1:L02 Date & Time gets defaulted when preforming a Factory Restore.

5.40.12.1:L03 It is not possible to select starting point when playing
back a recording while using multicast and h264.

5.40.12.1:L04 If the SD card is locked while there is a continuous
recording ongoing and then the recording is stopped while
the card is still locked, the recording continues and can
not be stopped.

5.40.12.1:L05 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

AXIS M1004-W Network Camera, version 5.40.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.5
================
5.40.5.3 is the first official production service release for the AXIS M1004-W

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not recommendable.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not work.

5.40.3:L28738 It's not possible to trigger action rules based on temperature.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot of small recordings can result in disc full. The automatic clean up will stop at that point and the user has to manually remove recordings.

5.40.5:L34090 DSCP value for Event/Alarm over IPv4 is always 0.

5.40.5:L34091 Changing DSCP values might prompt for password.

5.40.5:L34844 Privacy mask can't be added in Chrome.

5.40.5:L35825 Zoom bar is disabled until using zoom buttons.

5.40.5:L35026 Number of different configured video streams are limited by hardware.

AXIS P8221 Network I/O Audio Module, version 5.10

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.10
================
5.10 is the first official release for the AXIS P8221.

AXIS P1311 Network Camera, version 5.01.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.01.2
================

Improvements in 5.01.2 since 5.01.1
================
5.01.2:I01 Added support for a new internal memory type.

AXIS M1011 Network Camera, version 5.20.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.20.1
================

Corrections in 5.20.1 since 5.20
================
5.20.1:C01 Solved problem with video is streamed at a higher framerate than specified.

5.20.1:C02 RTP over RTSP over HTTP issue is solved.

5.20.1:C03 Corrected problem with AVHS One-click.

5.20.1:C04 Now Image appearance settings are restored when using "Restore" function.

5.20.1:C05 ONVIF setup/configuration issue is solved.

AXIS M3011 Network Camera, version 5.21

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.21
================

New features
================
5.21:F01 Added embedded AVHS (Axis Video Hosting System) client.

5.21:F02 Added ONVIF (Open Network Video Interface Forum) support including
metadata streaming over RTSP/RTP. This includes streaming of event
data, PTZ position and status data, and analytics data. Dynamic web
services discovery protocol as specified in ONVIF standard, which
follows WS-Discovery definitions (remote discovery will not be
supported), is also included.


5.21:F03 Added support for 802.1x.

5.21:F04 Functionality has been added making it possible for customer to upload
a customer logotype in the live view webpage.

Corrections
================
5.21:C01 It is possible now to see rotated image at the Motion detection
and exposure settings page.

AXIS M7001 Video Encoder, version 5.20

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.20:F01 Added embedded AVHS (Axis Video Hosting System) client.

5.20:F02 Added ONVIF (Open Network Video Interface Forum) support including
metadata streaming over RTSP/RTP. This includes streaming of event
data, PTZ position and status data, and analytics data. Dynamic web
services discovery protocol as specified in ONVIF standard, which
follows WS-Discovery definitions (remote discovery will not be
supported), is also included.

5.20:F03 Added support for 802.1x.

5.20:F04 Functionality has been added making it possible for customer to upload
a customer logotype in the live view webpage.

Corrections since 5.02
================
5.20:C01 It is possible now to see rotated image at the Motion detection
and exposure settings page.

5.20:C02 Dynamic Text Overlay works now as intended.

5.20:C03 Solved issue with time in the overlay should be the same as the NTP time.

5.20:C04 Overlay Image Upload is enabled.

5.20:C05 Fixed issue with sftpclient.

5.20:C06 Issue with RTP over RTSP over HTTP problem is fixed.

5.20:C07 Solved issue with Axis Metadata monitor.

5.20:C08 Incorrect RTP timestamping of the SPS/PPS frames issue is fixed.

5.20:C9 Included stability fix.
Viewing all 9471 articles