AXIS T8412 Installation Display, version T8412-6-724-937

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE T8412-6-724-937
================
Improvements in T8412-6-724-937 since T8412-6-724-931

Im01: Improved support for ONVIF.

RELEASE T8412-6-724-931
================
Improvements in T8412-6-724-931 since T8412-6-724-759

Im01: Added support for ONVIF.
Im02: Now using VAPIX for improved detection of camera capabilites.
IM03: Added bandwidth calculator in video image.
IM04: Added display of MAC address and Hostname.
IM05: Added advanced scripting tool for direct setting of camera parameters, including enabling AVHS.
IM06: Added custom connect delay for network search.
IM07: Improved PTZ control.

Corrections in T8412-6-724-931 since T8412-6-724-759

C01: Fixed illegal subnet bug.
C02: Fixed issue with max frame size.

RELEASE T8412-6-724-759
================
Improvements in T8412-6-724-759 since T8412-6-724-758

Im01: Added support for class B subnets.

RELEASE T8412-6-724-758
================
Improvements in T8412-6-724-758 since T8412-6-724-748

Im01: Added support for using HTTP ports other than port 80.
Im02: Improved performance when connecting to cameras over LAN.
IM03: Added support for multi-port video encoders, including preview of video sources.


Corrections in T8412-6-724-758 since T8412-6-724-748

C01: Fixed entry of symbols in usernames and passwords.
C02: Corrected display of features per camera model.

AXIS M1031-W Network Camera, version 5.20.3

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.20.3
================

Corrections in 5.20.3 since 5.20.2
================
5.20.3:C01 Updated firmware revision for wireless module.
5.20.3:C02 Corrected an issue with some SMTP servers like GMX regarding the "From" address.
5.20.3:C03 Correction of IP address filter issue.

AXIS M1011-W Network Camera, version 5.20.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.20.2
================

Corrections in 5.20.2 since 5.20.1
================
5.20.2:C01 Updated firmware revision for wireless module.
5.20.2:C02 Corrected an issue with some SMTP servers like GMX regarding the "From" address.
5.20.2:C03 Correction of IP address filter issue.

AXIS P7701 Network Video Decoder, version 5.07.4

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

RELEASE 5.07.4
================
5.07.4 is a production service release for AXIS P7701.

Corrections since 5.07.3
================
5.07.4:C01 Accept the "!" character in the password

5.07.4:C02 Corrected video stream continuity when switching between video sources

5.07.4:C03 Corrected a video issue when decoding high bitrate MJPEG over RTSP videostreams

AXIS P3367 Network Camera, version 5.40.3.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features/Functionality
================
5.40.3:F1 Events can now be triggered based on a temperature sensor.

5.40.3:F2 Events can now be triggered based on "Network lost".

Corrections since 5.40.3.1
================
5.40.3:C29780 Fixed a connection problem with the AVHS client that could
lead to infinite reconnect loop and criticials in the system log.

5.40.3:C32251 AVHS proxy should now work.

5.40.3:C33336 Fixed a performance problem with AVHS when using HTTPS.

5.40.3:C30984 Mute setting for Audio input gain is now working.

5.40.3:C31728 Administrators other than root can now configure ACAP
applications.

5.40.3:C32489 Fixed a problem with RTP tunneled over RTSP and HTTP that could
lead to terminated RTP sessions because of corrupt payload data.

5.40.3:C32529 Fixed a problem with UPnP NAT traversal that lead to NAT
traversal not working with several router brands.

5.40.3:C33232 Modifier #t for event notifications should now work as expected.

5.40.3:C33439 Fixed a problem with scheduled events not triggering at correct
time.

5.40.3:C33603 Fixed a problem with AVHS "always" register method.

5.40.3:C33603 Fixed a problem with the VAPIX I/O interface.

5.40.3:C33307 Fixed a problem with apps/focusd restarting and generating
critical log messages.

Known Bug/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not
recommendable.

5.40.3:L10049 With audio enabled, the initial connection latency is increased.

5.40.3:L24316 Check and repair is only available if the file system is ext4.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot
of small recordings can result in disc full. The automatic clean up will stop
at that point and the user has to manually remove recordings.

5.40.3:L28297 If you set max gain to a low value, e.g. 0, the IR cut filter
may not switch back on automatically.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not
work.

5.40.3:L29056 Local recording playback fails when using Motion JPEG + audio
with resolution 2048x1536 and higher. Use H.264 instead.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares
can degrade the performance of the system.

5.40.3:L24975 90 and 270 rotation can cause a drop in frame rate.

AXIS P5544 PTZ Dome Network Camera, version 5.41.2.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 5.41.2.1 since 5.41.2
================
5.41.2.1:C01 Minor corrections in the web GUI. (zoom bar)

RELEASE 5.41.2
================
5.41.2 is the first official release for AXIS P5544.

Known Bugs/Limitations
================
5.41.2:L01 Maximum brightness will not result in a white image.

5.41.2:L02 The NTP implementation will not synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.41.2:L03 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.41.2:L04 There is no boundary check when entering a motion detection window
name. If the name is more than 1024 charachters long, the parhand
application may restart.

5.41.2:L05 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.41.2:L06 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.
Workaround: Reload the Live View page.

5.41.2:L07 Daylight saving time does not work for Iran.

5.41.2:L08 Bitmap images have more contrast than the corresponding JPEG images.

5.41.2:L09 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.2:L10 Stream profile names are limited to alphanumerical characters.


5.41.2:L11 Constant bit rate might fluctuate more than 10%.

5.41.2:L12 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.41.2:L13 It is recommended to unmount the SD Card before ejecting it.

5.41.2:L14 Check and repair is only available if the file system is ext4.

5.41.2:L15 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.2:L16 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.2:L17 When the automatic IR cut filter enables/disables the IR cut filter,
it may trigger motion detection.

5.41.2:L18 An uploaded audio clip must be less than 1.5MB.

5.41.2:L19 To playback Matroska files generated by the camera on a computer, you
need to have the configuration file ('.conf') in the same folder as
the Matroska file ('.mkv'). For more information
see: http://www.axis.com/techsup/software/matroska/files/readme.txt

5.41.2:L20 Color parameter has no effect when pulling RTSP stream with color=0.

5.41.2:L21 Constant bit rate might fluctuate more than 10%.

5.41.2:L22 It is recommended to unmount the SD Card before ejecting it.

5.41.2:L23 Check and repair is only available if the file system is ext4.

5.41.2:L24 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.41.2:L25 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.41.2:L26 When making a snapshot during live view, with framerate and bandwidth
values enabled as text overlay, the values are shown as 0 in the snapshot.

5.41.2:L27 When using Chrome, Privacy masks page need to be refreshed in order to
show added privacy masks in the list.

5.41.2:L28 On some Windows 7 PC's IP Utility doesn't show the DUT when using IPv6.

5.41.2:L29 Expired or not yet valid client certificates will be uploaded
successfully instead of being rejected.

5.41.2:L30 DVM Honeywell generates criticals when accessing a camera during
the boot sequence.

5.41.2:L31 Script error when opening many live views

5.41.2:L32 Fixed an issue with an uploaded bitmap overlay which was made
partially transparent unconditionally.

5.41.2:L33 Automatic IR Cut Filter will not work if Auto Iris is off.

5.41.2:L34 Switching Auto Iris off may lead to the IR Cut Filter
being enabled/disabled.

5.41.2:L35 AMC sometimes crashes at startup on some versions of
Internet Explorer.

5.41.2:L35 Privacy masks are not visible in overview image.

5.41.2:L36 Overlay images are not visible in overview image.

5.41.2:L37 VMD only detects motion while in overview.

5.41.2:L38 Zoom not supported in overview mode.

AXIS M3203 Fixed Dome Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.40.9.2:F01 Added embedded AVHS (Axis Video Hosting System) client.

5.40.9.2:F02 Added support for 802.1x.

5.40.9.2:F03 Functionality has been added making it possible for customer to upload
a customer logotype in the live view webpage.

5.40.9.2:F04 Edge storage with support for CIFS/SMB (Microsoft Network share).

5.40.9.2:F05 The internal Event Management system has been redesigned and
VAPIX has been extended with a new Event-API based on Web-Services.

Utask has been removed and with that the possibility to start
scripts and applications from user.task.list.

The legacy user action rules in the camera will continue to work
but will not be visible in the camera user interface unless
converted to the new design.

Event Management user interface (GUI) has been redesigned.

For more information please see User's manual.

5.40.9.2:F06 Always Multicast. Provides the ability to multicast video
regardless of whether clients are accessing the streams or not.

5.40.9.2:F07 ONVIF 1.02 support.

5.40.9.2:F08 Server Report download. Possibility to download a ZIP-file server
report (with or without camera snapshot). This simplifies the
process of attaching the server report when submitting a support
ticket.

5.40.9.2:F09 Storage Management

1. Clean up policy is enabled by default and the default value
for the parameter is 1 week.

2. Parameter for clean up level is in the Plain Config and default
is set at approximately 90% of the storage device capacity.

3. The start time of a recording is updated when data is removed
due to clean up policy.

5.40.9.2:F10 Power line frequency has been introduced.

After setting initial root password, select the power line frequency
(50 Hz or 60 Hz) used at the location of the Axis product.
Selecting the right frequency will reduce image flicker if the product
is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note: After initial configuration, power line frequency can only
be changed through Plain Config (capture frequency parameter)
or by resetting the product to factory default.

Corrections in 5.40.9.2 since 5.12.1
================
5.40.9.2:C01 Encoding of email subject is now correct for some special
characters („åäö” etc.).

5.40.9.2:C02 Web services parameter is removed and thus status from the System
Overview as well. ONVIF is enabled by specifying an ONVIF
administrator in the Security -> ONVIF settings.

5.40.9.2:C03 RTP over RTSP over HTTP with other than default http port
works as expected.

5.40.9.2:C04 It is no longer necessary to restart the camera after configuring
default router parameter via VAPIX.

5.40.9.2:C05 Improved memory handling when using motion detection.

5.40.9.2:C06 Improved camera responsiveness.

5.40.9.2:C07 Configuration of time zone for Australia appears correctly
in the web interface.

5.40.9.2:C08 It is possible to use HTTPS and port forwarding.

5.40.9.2:C09 It is possible to add IP addresses to the IP filter list in
the web interface.

5.40.9.2:C10 Up to 127 characters can be used in the 'From email address'
field.

5.40.9.2:C11 Image with 800x450 resolution and 90 or 270 degrees rotation is
displayed correctly.

5.40:9:C12 Corrected the SMTP authentication issue with IPv6.

5.40.9.2:C13 Fixed an issue with an uploaded bitmap overlay which was made partially
transparent unconditionally.

5.40.9.2:C14 Corrected the issue of stopping and restarting running events when an
event or event server is added, modified or deleted.

5.40.9.2:C15 Bitmap images have same contrast as the corresponding JPEG images.

5.40.9.2:C16 The critical message, "Failed to write to file. Broken pipe" due to
short time between unregistering and registering to Axis Internet Dynamic DNS
will not be shown in the log.

5.40.9.2:C17 While installing AMC, clicking "View Certificate" in "Digital Signature Details"
will not show expired validation date for AAC and H.264.

5.40.9.2:C18 Double & are no longer present in HTTP notification. The Action rule gives
a valid URI.

5.40.9.2:C19 The error condition encountered when creating two similar action rules
(or by a copied action rule) has been fixed.

5.40.9.2:C20 Improved Web service deamon memory handling.

5.40.9.2:C21 Corrected an intermittent AVHS logging issue (since 5.40.9).

Known Bugs/Limitations
================
5.40.9.2:L01 The effect of backlight compensation on/off may not be noticable.

5.40.9.2:L02 Stream profile names are limited to alphanumerical characters.

5.40.9.2:L03 Limiting the bandwith to lower than 100kbit/s may lead to
losing contact with the camera.

5.25.1:L04 The web interface for ACAP Image Test application looks odd compared
to normal webinterface.

5.40.9.2:L05 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.2:L06 Video stream lost when clock is synchronizing to a past computer time.

5.40.9.2:L07 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.2:L08 Constant bit rate might fluctuate more than 10%. This will be
adjusted in a future release.

5.40.9.2:L09 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.2:L10 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L11 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

AXIS M3113/M3114/P8513/P8514 Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.40.9.2:F01 Edge storage with support for CIFS/SMB (Microsoft Network share).

5.40.9.2:F02 The internal Event Management system has been redesigned and
VAPIX has been extended with a new Event-API based on Web-Services.

Utask has been removed and with that the possibility to start
scripts and applications from user.task.list.

The legacy user action rules in the camera will continue to work
but will not be visible in the camera user interface unless
converted to the new design.

Event Management user interface (GUI) has been redesigned.

For more information please see User's manual.

5.40.9.2:F03 Always Multicast. Provides the ability to multicast video
regardless of whether clients are accessing the streams or not.

5.40.9.2:F04 ONVIF 1.02 support.

5.40.9.2:F05 Server Report download. Possibility to download a ZIP-file server
report (with or without camera snapshot). This simplifies the
process of attaching the server report when submitting a support
ticket.

5.40.9.2:F06 Storage Management

1. Clean up policy is enabled by default and the default value
for the parameter is 1 week.

2. Parameter for clean up level is in the Plain Config and default
is set at approximately 90% of the storage device capacity.

3. The start time of a recording is updated when data is removed
due to clean up policy.

5.40.9.2:F07 Power line frequency has been introduced.

After setting initial root password, select the power line frequency
(50 Hz or 60 Hz) used at the location of the Axis product.
Selecting the right frequency will reduce image flicker if the product
is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note: After initial configuration, power line frequency can only
be changed through Plain Config (capture frequency parameter)
or by resetting the product to factory default.

Corrections in 5.40.9.2 since 5.21
================
5.40.9.2:C01 Encoding of email subject is now correct for some special
characters („åäö” etc.).

5.40.9.2:C02 Web services parameter is removed and thus status from the System
Overview as well. ONVIF is enabled by specifying an ONVIF
administrator in the Security -> ONVIF settings.

5.40.9.2:C03 RTP over RTSP over HTTP with other than default http port works
as expected.

5.40.9.2:C04 It is no longer necessary to restart the camera after configuring
default router parameter via VAPIX.

5.40.9.2:C05 Improved memory handling when using motion detection.

5.40.9.2:C06 Improved camera responsiveness.

5.40.9.2:C07 Configuration of time zone for Australia appears correctly
in the web interface.

5.40.9.2:C08 It is possible to use HTTPS and port forwarding.

5.40.9.2:C09 It is possible to add IP addresses to the IP filter list in
the web interface.

5.40.9.2:C10 Up to 127 characters can be used in the 'From email address'
field.

5.40.9.2:C11 Image with 800x450 resolution and 90 or 270 degrees rotation is
displayed correctly.

5.40.9.2:C12 The DHCP option for IPV4 is removed when IPv6 is enabled
while IPv4 is disabled. The IPv6 address is included in the
mail body of an SMTP test mail.

5.40.9.2:C13 The event combination option "Include pre-trigger buffer" and
"Upload as long as the trigger is active" works together.

5.40.9.2:C14 Clicking on the save button after making changes to
the exposure window setting works correctly.

5.40.9.2:C15 Event or event server can now be added, modified or deleted
without all running events being stopped and restarted.

5.40.9.2:C16 Boundary check added when entering a motion detection window
name to prevent the parhand application to restart if the name is
more than 1024 charachters long.

5.40.9.2:C17 The NTP client will also synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.40.9.2:C18 Initial logging with creating self-signed certificate does not require
extra login as 'root' with password 'pass'.

5.40.9.2:C19 The parameter Message="" is no longer added to the http notification
URL when the Message field is empty.

5.40.9.2:C20 Double & are no longer present in HTTP notification. The Action rule
gives a valid URI.

5.40.9.2:C21 Videokeyframeinterval=1 with userdata enabled gives expected H.264 stream.

5.40.9.2:C22 Several improvements for stability.

5.40.9.2:C23 Handling sockets when running the ONVIF operation GetNetworkInterfaces
has been improved.

5.40.9.2:C24 Improved Web service deamon memory handling.

5.40.9.2:C25 Trigger data (SEI NAL) works as expected.

5.40.9.2:C26 Sending DHCP release has been adjusted for environments with DHCP
snooping.

5.40.9.2:C27 HTTP upload event with authentication works as expected.

5.40.9.2:C28 The trigger type for tampering is reported with the correct value
(T0:/ instead of T1:/).

5.40.9.2:C29 An adjustment for intermittently twitching stream during higher load has been made.

5.40.9.2:C30 Corrected an intermittent AVHS logging issue (since 5.40.9).

Known Bugs/Limitations
================
5.40.9.2:L01 The image is always showed with zero rotation at the Exposure
settings page.

5.40.9.2:L02 The effect of backlight compensation on/off may not be noticeable.

5.40.9.2:L03 Stream profile names are limited to alphanumerical characters.

5.40.9.2:L04 After re-configuring the date/time of the camera, the video stream might stop
with an RTSP session time out.
Workaround: Reconnect to the stream.

5.40.9.2:L05 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.

5.40.9.2:L06 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.2:L07 When the policy is set to HTTPS, this must apply to all three groups
admin, viewer and operator. If this is not the case and someone is
connecting with HTTP the re-direct page will not show.

5.40.9.2:L08 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the snapshot.
This happens for H.264 stream.

5.40.9.2:L09 Selected motion detection window changes/switches every time one chooses
'View All Windows' followed by 'View Selected Window'. Observerd behaviour
in Firefox and IE8 using Java.

5.40.9.2:L10 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.2:L11 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.2:L12 Constant bit rate might fluctuate more than 10%.

5.40.9.2:L13 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.2:L14 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.2:L15 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L16 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.2:L17 For ONVIF, GetCapabilities returns incorrect port number in XAddr
when web server port is changed to something else than 80.

AXIS P3301 Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 5.40.9.2 since 5.40.9
================
5.40.9.2:C01 Several improvements for stability.

5.40.9.2:C02 Handling of sockets when running the ONVIF operation GetNetworkInterfaces
has been improved.

5.40.9.2:C03 Web service deamon memory handling improved.

5.40.9.2:C04 Trigger data (SEI NAL) works as expected.

5.40.9.2:C05 Sending DHCP release has been adjusted for environments with DHCP
snooping.

5.40.9.2:C06 HTTP upload event with authentication works as expected.

5.40.9.2:C07 The error condition encountered when creating two similar action rules (or by a copied action rule) has been fixed.

5.40.9.2:C08 The problem of I/O port being stuck in active mode after a while of event triggering has been fixed.

5.40.9.2:C09 The trigger type for tampering is reported with the correct value
(T0:/ instead of T1:/).

5.40.9.2:C10 An adjustment for intermittently twitching stream during higher load has been made.

5.40.9.2:C11 Corrected an intermittent AVHS logging issue (since 5.40.9.1).

Known Bugs/Limitations
================
5.40.9.2:L01 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L02 With audio enabled, the initial connection latency increases.

5.40.9.2:L03 Color parameter has no effect when pulling RTSP stream with color=0.

AXIS M3113/M3114/P8513/P8514 Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.40.9.2:F01 Edge storage with support for CIFS/SMB (Microsoft Network share).

5.40.9.2:F02 The internal Event Management system has been redesigned and
VAPIX has been extended with a new Event-API based on Web-Services.

Utask has been removed and with that the possibility to start
scripts and applications from user.task.list.

The legacy user action rules in the camera will continue to work
but will not be visible in the camera user interface unless
converted to the new design.

Event Management user interface (GUI) has been redesigned.

For more information please see User's manual.

5.40.9.2:F03 Always Multicast. Provides the ability to multicast video
regardless of whether clients are accessing the streams or not.

5.40.9.2:F04 ONVIF 1.02 support.

5.40.9.2:F05 Server Report download. Possibility to download a ZIP-file server
report (with or without camera snapshot). This simplifies the
process of attaching the server report when submitting a support
ticket.

5.40.9.2:F06 Storage Management

1. Clean up policy is enabled by default and the default value
for the parameter is 1 week.

2. Parameter for clean up level is in the Plain Config and default
is set at approximately 90% of the storage device capacity.

3. The start time of a recording is updated when data is removed
due to clean up policy.

5.40.9.2:F07 Power line frequency has been introduced.

After setting initial root password, select the power line frequency
(50 Hz or 60 Hz) used at the location of the Axis product.
Selecting the right frequency will reduce image flicker if the product
is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note: After initial configuration, power line frequency can only
be changed through Plain Config (capture frequency parameter)
or by resetting the product to factory default.

Corrections in 5.40.9.2 since 5.21
================
5.40.9.2:C01 Encoding of email subject is now correct for some special
characters („åäö” etc.).

5.40.9.2:C02 Web services parameter is removed and thus status from the System
Overview as well. ONVIF is enabled by specifying an ONVIF
administrator in the Security -> ONVIF settings.

5.40.9.2:C03 RTP over RTSP over HTTP with other than default http port works
as expected.

5.40.9.2:C04 It is no longer necessary to restart the camera after configuring
default router parameter via VAPIX.

5.40.9.2:C05 Improved memory handling when using motion detection.

5.40.9.2:C06 Improved camera responsiveness.

5.40.9.2:C07 Configuration of time zone for Australia appears correctly
in the web interface.

5.40.9.2:C08 It is possible to use HTTPS and port forwarding.

5.40.9.2:C09 It is possible to add IP addresses to the IP filter list in
the web interface.

5.40.9.2:C10 Up to 127 characters can be used in the 'From email address'
field.

5.40.9.2:C11 Image with 800x450 resolution and 90 or 270 degrees rotation is
displayed correctly.

5.40.9.2:C12 The DHCP option for IPV4 is removed when IPv6 is enabled
while IPv4 is disabled. The IPv6 address is included in the
mail body of an SMTP test mail.

5.40.9.2:C13 The event combination option "Include pre-trigger buffer" and
"Upload as long as the trigger is active" works together.

5.40.9.2:C14 Clicking on the save button after making changes to
the exposure window setting works correctly.

5.40.9.2:C15 Event or event server can now be added, modified or deleted
without all running events being stopped and restarted.

5.40.9.2:C16 Boundary check added when entering a motion detection window
name to prevent the parhand application to restart if the name is
more than 1024 charachters long.

5.40.9.2:C17 The NTP client will also synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.40.9.2:C18 Initial logging with creating self-signed certificate does not require
extra login as 'root' with password 'pass'.

5.40.9.2:C19 The parameter Message="" is no longer added to the http notification
URL when the Message field is empty.

5.40.9.2:C20 Double & are no longer present in HTTP notification. The Action rule
gives a valid URI.

5.40.9.2:C21 Videokeyframeinterval=1 with userdata enabled gives expected H.264 stream.

5.40.9.2:C22 Several improvements for stability.

5.40.9.2:C23 Handling sockets when running the ONVIF operation GetNetworkInterfaces
has been improved.

5.40.9.2:C24 Improved Web service deamon memory handling.

5.40.9.2:C25 Trigger data (SEI NAL) works as expected.

5.40.9.2:C26 Sending DHCP release has been adjusted for environments with DHCP
snooping.

5.40.9.2:C27 HTTP upload event with authentication works as expected.

5.40.9.2:C28 The trigger type for tampering is reported with the correct value
(T0:/ instead of T1:/).

5.40.9.2:C29 An adjustment for intermittently twitching stream during higher load has been made.

5.40.9.2:C30 Corrected an intermittent AVHS logging issue (since 5.40.9).

Known Bugs/Limitations
================
5.40.9.2:L01 The image is always showed with zero rotation at the Exposure
settings page.

5.40.9.2:L02 The effect of backlight compensation on/off may not be noticeable.

5.40.9.2:L03 Stream profile names are limited to alphanumerical characters.

5.40.9.2:L04 After re-configuring the date/time of the camera, the video stream might stop
with an RTSP session time out.
Workaround: Reconnect to the stream.

5.40.9.2:L05 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.

5.40.9.2:L06 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.2:L07 When the policy is set to HTTPS, this must apply to all three groups
admin, viewer and operator. If this is not the case and someone is
connecting with HTTP the re-direct page will not show.

5.40.9.2:L08 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the snapshot.
This happens for H.264 stream.

5.40.9.2:L09 Selected motion detection window changes/switches every time one chooses
'View All Windows' followed by 'View Selected Window'. Observerd behaviour
in Firefox and IE8 using Java.

5.40.9.2:L10 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.2:L11 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.2:L12 Constant bit rate might fluctuate more than 10%.

5.40.9.2:L13 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.2:L14 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.2:L15 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L16 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.2:L17 For ONVIF, GetCapabilities returns incorrect port number in XAddr
when web server port is changed to something else than 80.

AXIS M3113/M3114/P8513/P8514 Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.40.9.2:F01 Edge storage with support for CIFS/SMB (Microsoft Network share).

5.40.9.2:F02 The internal Event Management system has been redesigned and
VAPIX has been extended with a new Event-API based on Web-Services.

Utask has been removed and with that the possibility to start
scripts and applications from user.task.list.

The legacy user action rules in the camera will continue to work
but will not be visible in the camera user interface unless
converted to the new design.

Event Management user interface (GUI) has been redesigned.

For more information please see User's manual.

5.40.9.2:F03 Always Multicast. Provides the ability to multicast video
regardless of whether clients are accessing the streams or not.

5.40.9.2:F04 ONVIF 1.02 support.

5.40.9.2:F05 Server Report download. Possibility to download a ZIP-file server
report (with or without camera snapshot). This simplifies the
process of attaching the server report when submitting a support
ticket.

5.40.9.2:F06 Storage Management

1. Clean up policy is enabled by default and the default value
for the parameter is 1 week.

2. Parameter for clean up level is in the Plain Config and default
is set at approximately 90% of the storage device capacity.

3. The start time of a recording is updated when data is removed
due to clean up policy.

5.40.9.2:F07 Power line frequency has been introduced.

After setting initial root password, select the power line frequency
(50 Hz or 60 Hz) used at the location of the Axis product.
Selecting the right frequency will reduce image flicker if the product
is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note: After initial configuration, power line frequency can only
be changed through Plain Config (capture frequency parameter)
or by resetting the product to factory default.

Corrections in 5.40.9.2 since 5.21
================
5.40.9.2:C01 Encoding of email subject is now correct for some special
characters („åäö” etc.).

5.40.9.2:C02 Web services parameter is removed and thus status from the System
Overview as well. ONVIF is enabled by specifying an ONVIF
administrator in the Security -> ONVIF settings.

5.40.9.2:C03 RTP over RTSP over HTTP with other than default http port works
as expected.

5.40.9.2:C04 It is no longer necessary to restart the camera after configuring
default router parameter via VAPIX.

5.40.9.2:C05 Improved memory handling when using motion detection.

5.40.9.2:C06 Improved camera responsiveness.

5.40.9.2:C07 Configuration of time zone for Australia appears correctly
in the web interface.

5.40.9.2:C08 It is possible to use HTTPS and port forwarding.

5.40.9.2:C09 It is possible to add IP addresses to the IP filter list in
the web interface.

5.40.9.2:C10 Up to 127 characters can be used in the 'From email address'
field.

5.40.9.2:C11 Image with 800x450 resolution and 90 or 270 degrees rotation is
displayed correctly.

5.40.9.2:C12 The DHCP option for IPV4 is removed when IPv6 is enabled
while IPv4 is disabled. The IPv6 address is included in the
mail body of an SMTP test mail.

5.40.9.2:C13 The event combination option "Include pre-trigger buffer" and
"Upload as long as the trigger is active" works together.

5.40.9.2:C14 Clicking on the save button after making changes to
the exposure window setting works correctly.

5.40.9.2:C15 Event or event server can now be added, modified or deleted
without all running events being stopped and restarted.

5.40.9.2:C16 Boundary check added when entering a motion detection window
name to prevent the parhand application to restart if the name is
more than 1024 charachters long.

5.40.9.2:C17 The NTP client will also synchronize to NTP servers that
signal an alarm condition (clock not synchronized) in its Leap
Indicator.

5.40.9.2:C18 Initial logging with creating self-signed certificate does not require
extra login as 'root' with password 'pass'.

5.40.9.2:C19 The parameter Message="" is no longer added to the http notification
URL when the Message field is empty.

5.40.9.2:C20 Double & are no longer present in HTTP notification. The Action rule
gives a valid URI.

5.40.9.2:C21 Videokeyframeinterval=1 with userdata enabled gives expected H.264 stream.

5.40.9.2:C22 Several improvements for stability.

5.40.9.2:C23 Handling sockets when running the ONVIF operation GetNetworkInterfaces
has been improved.

5.40.9.2:C24 Improved Web service deamon memory handling.

5.40.9.2:C25 Trigger data (SEI NAL) works as expected.

5.40.9.2:C26 Sending DHCP release has been adjusted for environments with DHCP
snooping.

5.40.9.2:C27 HTTP upload event with authentication works as expected.

5.40.9.2:C28 The trigger type for tampering is reported with the correct value
(T0:/ instead of T1:/).

5.40.9.2:C29 An adjustment for intermittently twitching stream during higher load has been made.

5.40.9.2:C30 Corrected an intermittent AVHS logging issue (since 5.40.9).

Known Bugs/Limitations
================
5.40.9.2:L01 The image is always showed with zero rotation at the Exposure
settings page.

5.40.9.2:L02 The effect of backlight compensation on/off may not be noticeable.

5.40.9.2:L03 Stream profile names are limited to alphanumerical characters.

5.40.9.2:L04 After re-configuring the date/time of the camera, the video stream might stop
with an RTSP session time out.
Workaround: Reconnect to the stream.

5.40.9.2:L05 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.

5.40.9.2:L06 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.2:L07 When the policy is set to HTTPS, this must apply to all three groups
admin, viewer and operator. If this is not the case and someone is
connecting with HTTP the re-direct page will not show.

5.40.9.2:L08 When snapshot is taken during live view with frame rate and bandwidth
values enabled as text overlay, the values are shown as 0 in the snapshot.
This happens for H.264 stream.

5.40.9.2:L09 Selected motion detection window changes/switches every time one chooses
'View All Windows' followed by 'View Selected Window'. Observerd behaviour
in Firefox and IE8 using Java.

5.40.9.2:L10 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.2:L11 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.2:L12 Constant bit rate might fluctuate more than 10%.

5.40.9.2:L13 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.2:L14 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.2:L15 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L16 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.2:L17 For ONVIF, GetCapabilities returns incorrect port number in XAddr
when web server port is changed to something else than 80.

AXIS M3014 Network Camera, version 5.40.9.2

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

New Features
================
5.40.9.2:F01 Edge storage with support for CIFS/SMB (Microsoft Network share).

5.40.9.2:F02 The internal Event Management system has been redesigned and
VAPIX has been extended with a new Event-API based on Web-Services.

Utask has been removed and with that the possibility to start
scripts and applications from user.task.list.

The legacy user action rules in the camera will continue to work
but will not be visible in the camera user interface unless
converted to the new design.

Event Management user interface (GUI) has been redesigned.

For more information please see User's manual.

5.40.9.2:F03 Always Multicast. Provides the ability to multicast video
regardless of whether clients are accessing the streams or not.

5.40.9.2:F04 ONVIF 1.02 support.

5.40.9.2:F05 Server Report download. Possibility to download a ZIP-file server
report (with or without camera snapshot). This simplifies the
process of attaching the server report when submitting a support
ticket.

5.40.9.2:F06 Storage Management

1. Clean up policy is enabled by default and the default value
for the parameter is 1 week.

2. Parameter for clean up level is in the Plain Config and default
is set at approximately 90% of the storage device capacity.

3. The start time of a recording is updated when data is removed
due to clean up policy.

5.40.9.2:F07 Power line frequency has been introduced.

After setting initial root password, select the power line frequency
(50 Hz or 60 Hz) used at the location of the Axis product.
Selecting the right frequency will reduce image flicker if the product
is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note: After initial configuration, power line frequency can only
be changed through Plain Config (capture frequency parameter)
or by resetting the product to factory default.

Corrections in 5.40.9.2 since 5.21
================
5.40.9.2:C01 Encoding of email subject is now correct for some special
characters („åäö” etc.).

5.40.9.2:C02 Web services parameter is removed and thus status from the System
Overview as well. ONVIF is enabled by specifying an ONVIF
administrator in the Security -> ONVIF settings.

5.40.9.2:C03 RTP over RTSP over HTTP with other than default http port works
as expected.

5.40.9.2:C04 It is no longer necessary to restart the camera after configuring
default router parameter via VAPIX.

5.40.9.2:C05 Improved memory handling when using motion detection.

5.40.9.2:C06 Improved camera responsiveness.

5.40.9.2:C07 Configuration of time zone for Australia appears correctly
in the web interface.

5.40.9.2:C08 It is possible to use HTTPS and port forwarding.

5.40.9.2:C09 It is possible to add IP addresses to the IP filter list in
the web interface.

5.40.9.2:C10 Up to 127 characters can be used in the 'From email address'
field.

5.40.9.2:C11 Image with 800x450 resolution and 90 or 270 degrees rotation is
displayed correctly.

5.40.9.2:C12 It is possible to use a space in the upload path for an
ftp server.

5.40.9.2:C13 The DHCP option for IPV4 is removed when IPv6 is enabled
while IPv4 is disabled. The IPv6 address is included in the
mail body of an SMTP test mail.

5.40.9.2:C14 The event combination option "Include pre-trigger buffer" and
"Upload as long as the trigger is active" works together.

5.40.9.2:C15 Clicking on the save button after making changes to
the exposure window setting works correctly.

5.40.9.2:C16 Event or event server can now be added, modified or deleted
without all running events being stopped and restarted.

5.40.9.2:C17 Boundary check added when entering a motion detection window
name to prevent the parhand application to restart if the name is
more than 1024 charachters long.

5.40.9.2:C18 Initial logging with creating self-signed certificate does not require
extra login as 'root' with password 'pass'.

5.40.9.2:C19 The parameter Message="" is no longer added to the http notification
URL when the Message field is empty.

5.40.9.2:C20 Double & are no longer present in HTTP notification. The Action rule
gives a valid URI.

5.40.9.2:C21 Videokeyframeinterval=1 with userdata enabled gives expected H.264 stream.

5.40.9.2:C22 Several improvements for stability.

5.40.9.2:C23 Handling sockets when running the ONVIF operation GetNetworkInterfaces
has been improved.

5.40.9.2:C24 Improved Web service deamon memory handling.

5.40.9.2:C25 Trigger data (SEI NAL) works as expected.

5.40.9.2:C26 Sending DHCP release has been adjusted for environments with DHCP
snooping.

5.40.9.2:C27 HTTP upload event with authentication works as expected.

5.40.9.2:C28 An adjustment for intermittently twitching stream during higher load has been made.

5.40.9.2:C29 Corrected an intermittent AVHS logging issue (since 5.40.9).

Known Bugs/Limitations
================
5.40.9.2:L01 The image is always showed with zero rotation at the Exposure
settings page.

5.40.9.2:L02 The effect of backlight compensation on/off may not be noticeable.

5.40.9.2:L03 Stream profile names are limited to alphanumerical characters.

5.40.9.2:L04 After changing the date/time of the camera, the video stream will
stop after 60 seconds with an RTSP session time out. It does not
matter if the media stream is started before or after the time is
changed.
Workaround: Reboot the camera after the time has been changed
manually or by NTP.

5.40.9.2:L05 AXIS Media Control client may stop displaying the H.264 video
stream after the PC has been locked.

5.40.9.2:L06 Daylight saving time does not work for Iran.

5.40.9.2:L07 If a customer is trying to upload a very large file instead of a
valid language file, a "404 page cannot be displayed" page is
shown.

5.40.9.2:L08 Synchronizing camera time with a computertime or NTP-server time that
is ahead of camera time will cause clients to stop. Computertime
or NTP-server time that is behind camera time is not affected.
Workaround: Reload the page to start the stream again.

5.40.9.2:L09 Multicast for ipv6 works only if ipv4 is also enabled.

5.40.9.2:L10 Date modifiers "%m-%d-%Y" are not formatted correctly when used
with folder name, SMTP subject and message.

5.40.9.2:L11 Adding color=0 to the rtsp video link will not result in
black&white image. Set color to 0 in Camera Settings instead.

5.40.9.2:L12 Video stream lost when clock is synchronizing to a past
computer time.
Expected: Time is synchronized and video stream is up.
Actual: Video stream is lost.

5.40.9.2:L13 Frame Size Control does not affect the size of the snapshot taken with
the upper right control that can be added to the Live View.

5.40.9.2:L14 Constant bit rate might fluctuate more than 10%.

5.40.9.2:L15 Events triggered at the same time, will by default settings
share the same filename. This may result in upload of corrupted
image.

5.40.9.2:L16 If RTSP authentication is switched off, streaming H.264 with QuickTime
and other Apple compatible clients will not work as they require
authentication of the RTSP, but do not allow HTTP authentication.

5.40.9.2:L17 When using action rule resulting in short recordings, it is recommended
to extend post-event time.

5.40.9.2:L18 For ONVIF, GetCapabilities returns incorrect port number in XAddr
when web server port is changed to something else than 80.

AXIS M3025-VE Network Camera, version 5.40.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.5
================
5.40.5 is the first official production service release for the AXIS M3025-VE.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not recommendable.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not work.

5.40.3:L28738 It's not possible to trigger action rules based on temperature.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot of small recordings can result in disc full. The automatic clean up will stop at that point and the user has to manually remove recordings.

5.40.5:L32999 Script error when pressing Create Certificate Request.

5.40.5:L34090 DSCP value for Event/Alarm over IPv4 is always 0.

5.40.5:L34091 Changing DSCP values might prompt for password.

5.40.5:L34844 Privacy mask can't be added in Chrome.

5.40.5:L35026 Number of different configured video streams are limited by hardware.

5.40.5:L35825 Zoom bar is disabled until using zoom buttons.

5.40.5:L36083 Compression input field accepts all type of characters
Description: No warning is shown if Compression is set to Negative number, higher than MAX or a non-integer.

5.40.5:L48986 Preset Reached event may trigger before reaching preset.

AXIS M3024-LVE Network Camera, version 5.40.5

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.40.5
================
5.40.5 is the first official production service release for the AXIS M3024-LVE.

Features
================

Known Bugs/Limitations
================
5.40.3:L18122 Removing and reinserting SD card during recording is not recommendable.

5.40.3:L26145 Moving a view area doesn't always work as expected.

5.40.3:L27653 Multiple simultaneous recordings to SD cards and network shares can degrade the performance of the system.

5.40.3:L27901 Using modifiers like %c in a network share upload event does not work.

5.40.3:L28738 It's not possible to trigger action rules based on temperature.

5.40.3:L29580 A combination of a high bandwidth continuous recording and a lot of small recordings can result in disc full. The automatic clean up will stop at that point and the user has to manually remove recordings.

5.40.5:L32999 Script error when pressing Create Certificate Request.

5.40.5:L34090 DSCP value for Event/Alarm over IPv4 is always 0.

5.40.5:L34091 Changing DSCP values might prompt for password.

5.40.5:L34844 Privacy mask can't be added in Chrome.

5.40.5:L35026 Number of different configured video streams are limited by hardware.

5.40.5:L35825 Zoom bar is disabled until using zoom buttons.

5.40.5:L36083 Compression input field accepts all type of characters.
Description: No warning is shown if Compression is set to Negative number, higher than MAX or a non-integer.

5.40.5:L44631 IR illumination action when IR illumination is disabled.
Description: IR cut filter switches even when IR Illumination is disabled

5.40.5:L48986 Preset Reached event may trigger before reaching preset.

M7016, version 5.51.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.51.1
================
5.51.1 is the first official relase for AXIS M7016

Known Bugs/Limitations
================
5.51.1:L01
Zoom is shown on live view page when using java applet as default viewer, even
though it is not supported.

5.51.1:L02
Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause
missing frames/sequences.

5.51.1:L03
90 and 270 rotation can cause a drop in frame rate.

5.51.1:L04
Multiple simultaneous recordings to SD cards and network shares can degrade the
performance of the system.

5.51.1:L05
Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are
UNIX standard.

5.51.1:L06
When Guard Tour is active, it is not possible to use PTZ controls with Viewer
access rights.

5.51.1:L07
If the device has ongoing continuous recordings and the device is restarted
using the restart option in web interface, the current part of recordings(block)
can not be accessed or downloaded through the web interface.

5.51.1:L08
Stream profile names are limited to alphanumerical characters.

5.51.1:L09
Recordings made with firmware earlier than 5.20 will not be readable on the SD
Card from firmware 5.40 and onward. Backup important recordings and reformat the
SD Card after the firmware upgrade.

5.51.1:L10
Check and repair is only available if the file system is ext4.

5.51.1:L11
The AXIS Media Control client may stop displaying the H.264 video stream after
the PC has been locked.

5.51.1:L12
Live view does not work with QuickTime player using default settings.
Workaround: Disable Direct3D acceleration in Quicktime.

5.51.1:L13
When using an action rule results in short recordings, it is recommended to
extend post-event time.

5.51.1:L14
To avoid corrupt recordings, it is recommended to unmount the SD Card before
ejecting it.

5.51.1:L15
For actions based on PTZ events, it is not possible to use the #P (PTZ preset
name) and #p (PTZ preset number) modifiers in the file names for network share
uploads.

5.51.1:L16
Downgrading from 5.50.x to a 5.40.x firmware version will cause an AVHS/O3C
connection to drop. Do not downgrade an AVHS/O3C connected camera unless you can
do a factory reset locally on the camera.

5.51.1:L17
It's not recommended to downgrade to previous firmware when having HTTPS
enabled.

5.51.1:L18
Video overlay text size is a global setting and can not be set for each stream
profile.

5.51.1:L19
If text overlay is more than 460 characters long, no text will be displayed

5.51.1:L20
Private keys need to be in a PKCS#1 format in order to function.

5.51.1:L21
The resolutions of the pre-defined profiles have changed. Quality, Balanced and
Bandwidth uses default resolution, which is equal to the highest available
resolution. Mobile uses the lowest resolution.

5.51.1:L22
If downgrading to previous firmware version, a factory default is recommended
after performing the downgrade.

5.51.1:L23
For network share passwords, the character comma (,) is not allowed.

5.51.1:L24
Not possible to view live or recorded video in Internet Explorer 10 Modern UI in
Microsoft Windows 8.

5.51.1:L25
Extented Driver Specific settings are missing under PTZ, Advanced, Device
settings. Parameters are available in plain configuration.

5.51.1:L26
Using Java applet as a viewer, the button Zoom Wide does not zoom out fully.

5.51.1:L27
Unclear error message when uploading audio clip with already existing name.

5.51.1:L28
When using action rules, network trigger does not work.

Supported AXIS VAPIX API Image Resolutions for AXIS M7016
================

AXIS P5414-E PTZ Dome Network Camera, version 5.55.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Known Bugs/Limitations
================
5.55.1:L01 When the automatic IR cut filter enables/disables the
IR cut filter, it may trigger motion detection.

5.55.1:L02 Using control queue with Java Applet may result in wrong
queue positions if switching between admin and viewer users.

5.55.1:L03 Loading the Live View page sometimes show the wrong type
of zoom/focus/iris control bars if the device is not fully
booted up. Reloading the web page will resolve the issue.

5.55.1:L04 Video motion detection will detect objects behind privacy masks.

5.55.1:L05 The live stream is not updated when using tilt arrows in
some update revisions of IE9. The stream will update again
once the mouse pointer is not hovering over the arrow icon.

5.55.1:L06 The ipv6.class field will have the same value in all IPv6
packages. The class field value depends on the value of
the DSCP setting.

5.55.1:L07 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.55.1:L08 All installed ACAP will need to be re-installed after
next firmware upgrade.

5.55.1:L09 When using an action rule resulting in short recordings,
it is recommended to extend post-trigger time.

5.55.1:L10 Video performance might be degraded when ip address
filtering is enabled. Disable network logging in plain
config to increase performance.

5.55.1:L11 Upgrading the camera in IE10 from a slow disk such as a
network-share might cause the upgrade info webpage to
timeout. The camera will still be upgraded.

5.55.1:L12 Creating a stream profile with special characters does
not work in Internet Explorer

5.55.1:L13 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

5.55.1:L14 Not possible to view live or recorded video in Internet
Explorer 10 Modern UI in Microsoft Windows 8.

5.55.1:L15 The Audio tab web page indicates loading until moving to
a different tab or page.

Axis M3026-VE Network Camera, version 5.55.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Release 5.55.1
================
5.55.1 is the first official production release for the AXIS M3026-VE.

Known Bugs/Limitations
================
5.55.1:L01
Not possible to view live or recorded video in Internet Explorer 10 Modern UI
in Microsoft Windows 8.

5.55.1:L02
When using limited bandwidth modifier #r shows wrong value.

5.55.1:L03
Video performance might be degraded when network logging and ip address
filtering are enabled at the same time. Disable the log
(http://cam_IP/admin/config.shtml?group=Network) to increase performance.

5.55.1:L04
Removing and reinserting SD card during recording is not recommended.

5.55.1:L05
Multiple simultaneous recordings to SD cards and network shares can degrade
the performance of the system.

5.55.1:L06
Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are
UNIX standard.

5.55.1:L07
To avoid corrupt recordings, it is recommended to unmount the SD Card before
ejecting it.

5.55.1:L08
Video overlay text size is a global setting and can not be set for each stream
profile.

5.55.1:L09
If text overlay is more than 460 characters long, no text will be displayed.

5.55.1:L10
Live view does not work with QuickTime player using default settings.
Workaround: Disable Direct3D acceleration in Quicktime.

P7216, version 5.51.1.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Corrections in 5.51.1.1 since 5.51.1
================
5.51.1.1:C01
It is not longer necessary to restart the video encoder when changing between
SFP and RJ45.

Known Bugs/Limitations
================
5.51.1.1:L01
Zoom is shown on live view page when using java applet as default viewer, even
though it is not supported.

5.51.1.1:L02
Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause
missing frames/sequences.

5.51.1.1:L03
90 and 270 rotation can cause a drop in frame rate.

5.51.1.1:L04
Multiple simultaneous recordings to SD cards and network shares can degrade the
performance of the system.

5.51.1.1:L05
Windows Network Shares do not handle all modifiers e.g. %c, since modifiers are
UNIX standard.

5.51.1.1:L06
When Guard Tour is active, it is not possible to use PTZ controls with Viewer
access rights.

5.51.1.1:L07
If the device has ongoing continuous recordings and the device is restarted
using the restart option in web interface, the current part of recordings(block)
can not be accessed or downloaded through the web interface.

5.51.1.1:L08
Stream profile names are limited to alphanumerical characters.

5.51.1.1:L09
Recordings made with firmware earlier than 5.20 will not be readable on the SD
Card from firmware 5.40 and onward. Backup important recordings and reformat the
SD Card after the firmware upgrade.

5.51.1.1:L10
Check and repair is only available if the file system is ext4.

5.51.1.1:L11
The AXIS Media Control client may stop displaying the H.264 video stream after
the PC has been locked.

5.51.1.1:L12
Live view does not work with QuickTime player using default settings.
Workaround: Disable Direct3D acceleration in Quicktime.

5.51.1.1:L13
When using an action rule results in short recordings, it is recommended to
extend post-event time.

5.51.1.1:L14
To avoid corrupt recordings, it is recommended to unmount the SD Card before
ejecting it.

5.51.1.1:L15
For actions based on PTZ events, it is not possible to use the #P (PTZ preset
name) and #p (PTZ preset number) modifiers in the file names for network share
uploads.

5.51.1.1:L16
Downgrading from 5.50.x to a 5.40.x firmware version will cause an AVHS/O3C
connection to drop. Do not downgrade an AVHS/O3C connected camera unless you can
do a factory reset locally on the camera.

5.51.1.1:L17
It's not recommended to downgrade to previous firmware when having HTTPS
enabled.

5.51.1.1:L18
Video overlay text size is a global setting and can not be set for each stream
profile.

5.51.1.1:L19
If text overlay is more than 460 characters long, no text will be displayed

5.51.1.1:L20
Private keys need to be in a PKCS#1 format in order to function.

5.51.1.1:L21
The resolutions of the pre-defined profiles have changed. Quality, Balanced and
Bandwidth uses default resolution, which is equal to the highest available
resolution. Mobile uses the lowest resolution.

5.51.1.1:L22
If downgrading to previous firmware version, a factory default is recommended
after performing the downgrade.

5.51.1.1:L23
For network share passwords, the character comma (,) is not allowed.

5.51.1.1:L24
Not possible to view live or recorded video in Internet Explorer 10 Modern UI in
Microsoft Windows 8.

5.51.1.1:L25
Extented Driver Specific settings are missing under PTZ, Advanced, Device
settings. Parameters are available in plain configuration.

5.51.1.1:L26
Using Java applet as a viewer, the button Zoom Wide does not zoom out fully.

5.51.1.1:L27
Unclear error message when uploading audio clip with already existing name.

5.51.1.1:L28
Occasionally, G711 audio can lag when using Java applet.

5.51.1.1:L29
When using action rules, network trigger does not work.

Supported AXIS VAPIX API Image Resolutions for AXIS P7216
================

AXIS Q6044 PTZ Dome Network Camera, version 5.55.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Known Bugs/Limitations
================
5.55.1:L01 When the automatic IR cut filter enables/disables the
IR cut filter, it may trigger motion detection.

5.55.1:L02 Using control queue with Java Applet may result in wrong
queue positions if switching between admin and viewer users.

5.55.1:L03 Loading the Live View page sometimes show the wrong type
of zoom/focus/iris control bars if the device is not fully
booted up. Reloading the web page will resolve the issue.

5.55.1:L04 Video motion detection will detect objects behind privacy masks.

5.55.1:L05 The live stream is not updated when using tilt arrows in
some update revisions of IE9. The stream will update again
once the mouse pointer is not hovering over the arrow icon.

5.55.1:L06 The ipv6.class field will have the same value in all IPv6
packages. The class field value depends on the value of
the DSCP setting.

5.55.1:L07 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.55.1:L08 All installed ACAP will need to be re-installed after
next firmware upgrade.

5.55.1:L09 When using an action rule resulting in short recordings,
it is recommended to extend post-trigger time.

5.55.1:L10 Video performance might be degraded when ip address
filtering is enabled. Disable network logging in plain
config to increase performance.

5.55.1:L11 Upgrading the camera in IE10 from a slow disk such as a
network-share might cause the upgrade info webpage to
timeout. The camera will still be upgraded.

5.55.1:L12 Creating a stream profile with special characters does
not work in Internet Explorer

5.55.1:L13 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

5.55.1:L14 Not possible to view live or recorded video in Internet
Explorer 10 Modern UI in Microsoft Windows 8.

5.55.1:L15 The Audio tab web page indicates loading until moving to
a different tab or page.

AXIS Q6045 PTZ Dome Network Camera, version 5.55.1

$
0
0
This firmware is now available. Please visit the product's support page on www.axis.com for the download, full release notes and installation instructions.

Known Bugs/Limitations
================
5.55.1:L01 When the automatic IR cut filter enables/disables the
IR cut filter, it may trigger motion detection.

5.55.1:L02 Using control queue with Java Applet may result in wrong
queue positions if switching between admin and viewer users.

5.55.1:L03 Loading the Live View page sometimes show the wrong type
of zoom/focus/iris control bars if the device is not fully
booted up. Reloading the web page will resolve the issue.

5.55.1:L04 Video motion detection will detect objects behind privacy masks.

5.55.1:L05 The live stream is not updated when using tilt arrows in
some update revisions of IE9. The stream will update again
once the mouse pointer is not hovering over the arrow icon.

5.55.1:L06 The ipv6.class field will have the same value in all IPv6
packages. The class field value depends on the value of
the DSCP setting.

5.55.1:L07 Recording streams to SD Card with a total bit rate above
12Mbit/sec may cause missing frames/sequences.

5.55.1:L08 All installed ACAP will need to be re-installed after
next firmware upgrade.

5.55.1:L09 When using an action rule resulting in short recordings,
it is recommended to extend post-trigger time.

5.55.1:L10 Video performance might be degraded when ip address
filtering is enabled. Disable network logging in plain
config to increase performance.

5.55.1:L11 Upgrading the camera in IE10 from a slow disk such as a
network-share might cause the upgrade info webpage to
timeout. The camera will still be upgraded.

5.55.1:L12 Creating a stream profile with special characters does
not work in Internet Explorer

5.55.1:L13 When requesting a videostream using video.cgi, the
parameter color=0 will not result in a black&white image.

5.55.1:L14 Not possible to view live or recorded video in Internet
Explorer 10 Modern UI in Microsoft Windows 8.

5.55.1:L15 Detector limitations
* Only one instance of the detectors "object removed",
"enter/exit", "fence" and "counter" can be activated
at the same time.
* Adjust the object size to the size of the objects to
be detected.
* The detected size might differ from the actual size,
depending on the shape of the object.
* Up to 16 detected objects can be displayed at
the same time.
* The video analysis capability may degrade in the
following conditions:
- The object is close to the camera.
- The object color or brightness is similar
to the background.
- A major scene change.
- The object is hidden behind other objects.
- Two or more objects overlap.
- The object is moving too fast.
- Reflection, blur or shadow due to direct sunlight,
illumination or headlamps.
- Severe snow, rain, wind, dawn or dusk.

5.55.1:L16 IR-cut filter will block in day-mode if it switches on/off
multiple times within 5 minutes in order to protect the
hardware. The IR-cut filter will unlock again after detecting
bright conditions or a user resend the "auto IR-cut" command.

5.55.1:L17 Area of interest will be reset when updating the object
size without saving first in the "object removed",
"enter/exit", "fence" and "counter" detectors.

5.55.1:L18 The Audio tab web page indicates loading until moving to
a different tab or page.
Viewing all 9471 articles